Arthroscopic Suture Fixation With Autograft Augmentation Reconstruction for Delayed Tibial Avulsion Fractures of the Posterior Cruciate Ligament

Author:

Bi Mingguang1,Zhao Chen2,Chen Jihang2,Hong Zheping2,Wang Zhen2,Gan Kaifeng1,Tong Yu2,Bi Qing2

Affiliation:

1. Lihuili Hospital, Ningbo Medical Center, Ningbo University School of Medicine, Ningbo, China.

2. Department of Orthopaedic Surgery, Zhejiang Provincial People’s Hospital and People’s Hospital of Hangzhou Medical College, Hangzhou, China.

Abstract

Background: The optimal surgical treatment of delayed avulsion fractures of the posterior cruciate ligament (PCL) is still controversial. Purpose: To evaluate the clinical results of arthroscopic suture fixation of tibial avulsion fractures of the PCL with autograft augmentation reconstruction. Study Design: Case series; Level of evidence, 4. Methods: From January 2013 to February 2017, we treated 15 patients with delayed tibial avulsion fractures of the PCL arthroscopically through posteromedial and posterolateral portals. The PCL and avulsion bone fragment were fixed with No. 2 nonabsorbable FiberWire sutures that were pulled out through a single tibial bone tunnel and fixed on a small Endobutton. Concomitantly, anatomic PCL augmentation reconstruction was performed, and the graft was pulled out through the same tunnel and fixed with an interference screw. Knee stability was assessed using the posterior drawer test, and the side-to-side difference was determined using a KT-1000 arthrometer with 134 N of posterior force at 30° of knee flexion. The International Knee Documentation Committee (IKDC) 2000 subjective form and Lysholm scale were used to evaluate clinical outcomes at follow-up. Overall, 12 patients were enrolled for analysis. The mean follow-up period was 34.4 months (range, 26-49 months). Results: At the final follow-up, 2 patients encountered 10° terminal flexion limitations. All patients had negative posterior drawer test results. The KT-1000 arthrometer side-to-side difference was significantly decreased from 8.25 ± 1.96 mm preoperatively to 1.08 ± 0.86 mm at the last follow-up ( P < .001). The mean IKDC and Lysholm scores, respectively, increased from 54.67 ± 7.13 and 53.50 ± 7.90 preoperatively to 91.13 ± 3.78 and 94.25 ± 3.32 at the final follow-up ( P < .001 for both). Conclusion: Arthroscopic suture fixation with autograft augmentation reconstruction for delayed tibial avulsion fractures of the PCL showed good clinical stability and function in this study.

Publisher

SAGE Publications

Subject

Orthopedics and Sports Medicine

Cited by 4 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3