Differences in Patellofemoral Alignment Between Static and Dynamic Extension Positions in Patients With Patellofemoral Pain

Author:

Chen Yurou1,Li Jia12,Yang Haitao1,Lv Fajin1,Sheng Bo1,Lv Furong1

Affiliation:

1. Department of Radiology, The First Affiliated Hospital of Chongqing Medical University, Chongqing, PR China

2. Department of Orthopaedic Surgery, the First Affiliated Hospital of Chongqing Medical University, Chongqing, PR China

Abstract

Background: Considering that patellofemoral pain (PFP) is related to dynamic factors, dynamic extension on 4-dimensional computed tomography (4-DCT) may better reflect the influence of muscles and surrounding soft tissue than static extension. Purpose: To compare the characteristics of patellofemoral alignment between the static and dynamic knee extension position in patients with PFP and controls via 4-DCT. Study Design: Cross-sectional study; Level of evidence, 3. Methods: Included were 39 knees (25 patients) with PFP and 37 control knees (24 participants). For each knee, an image of the dynamic extension position (a single frame of the knee in full extension [flexion angle of -5° to 0°] selected from 21 frames of continuous images acquired by 4-DCT during active flexion and extension) and an image of the static extension position (acquired using the same equipment with the knee fully extended and the muscles relaxed) were selected. Patellofemoral alignment was evaluated between the dynamic and static extension positions and between the PFP and control groups with the following parameters: patella-patellar tendon angle (P-PTA), Blackburne-Peel ratio, bisect-offset (BO) index, lateral patellar tilt (LPT), and tibial tuberosity-trochlear groove (TT-TG) distance. Results: In both PFP patients and controls, the P-PTA, Blackburne-Peel ratio, and BO index in the static extension position were significantly lower ( P < .001 for all), while the LPT and TT-TG distance in the static extension position were significantly higher ( P ≤ .034 and P < .001, respectively) compared with values in the dynamic extension position. In the comparison between groups, only P-PTA in the static extension position was significantly different (134.97° ± 4.51° [PFP] vs 137.82° ± 5.63° [control]; P = .027). No difference was found in the rate of change from the static to the dynamic extension position of any parameter between the study groups. Conclusion: The study results revealed significant differences in patellofemoral alignment characteristics between the static and dynamic extension positions of PFP patients and controls. Multiplanar measurements may have a role in subsequent patellofemoral alignment evaluation.

Funder

Chongqing Science and Technology Commission

Publisher

SAGE Publications

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3