Measurement of Tibial Tuberosity–Trochlear Groove Offset Distance by Weightbearing Cone-Beam Computed Tomography Scan

Author:

Marzo John M.1,Kluczynski Melissa A.1,Notino Anthony1,Bisson Leslie J.1

Affiliation:

1. State University of New York at Buffalo, Buffalo, New York, USA.

Abstract

Background: Computed tomography (CT) scans are useful for objectively measuring bone alignment because they show bone detail particularly well, and these scans have been used extensively to assess patellar orientation. The tibial tubercle–trochlear groove (TT-TG) offset distance has been shown to be influenced by knee flexion and weightbearing, yet conventional CT scans are obtained with the subject relaxed, supine, and with the knee in full extension. A new cone-beam CT scanner has been designed to allow for weightbearing images, potentially providing a more physiologically relevant assessment of patellofemoral alignment. Purpose/Hypothesis: The purpose of this study was to measure the TT-TG offset in healthy individuals without any history of knee complaints when CT scans were obtained while fully weightbearing on a flexed knee. Our hypothesis was that the TT-TG offset measurement in these healthy knees would be reproducible and less than the historically reported normal range. Study Design: Cross-sectional study; Level of evidence, 3. Methods: Twenty healthy volunteers without any history of knee complaint were recruited to undergo a weightbearing cone-beam CT scan of the knee flexed at 30°. The scans were reviewed by a radiologist and an orthopaedic surgeon, and TT-TG offset was measured using the digital tools of a picture archiving and communication system. Paired t tests were used to compare TT-TG offset on 2 separate occasions for both raters. Inter- and intrarater reliability were assessed using a 2-way mixed-effects model intraclass correlation coefficient with corresponding 95% confidence intervals for TT-TG offset. Results: The mean TT-TG offset was 2.7 mm. There were no statistically significant differences in TT-TG offset between raters ( Prater1 = .70; Prater2 = .49) and time of read ( Ptime1 = .83; Ptime2 = .19). Good to moderate interrater reliability was found at the time of both reads, and good intrarater reliability was found for both raters. Conclusion: When measured by CT scan and obtained from a subject while weightbearing on a flexed knee, the TT-TG offset is reproducible and the distance is less than that obtained via a conventional CT scan.

Publisher

SAGE Publications

Subject

Orthopedics and Sports Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3