Continuous-Loop Tape Technique Has Greater Stiffness and Less Elongation Compared With Tied-Suture Fixation of Full-Thickness All–Soft Tissue Quadriceps Tendon Autografts

Author:

Gibbs Christopher M.1,Winkler Philipp W.12,Tisherman Robert T.1,Chan Calvin K.3,Diermeier Theresa A.12,Debski Richard E.13,Musahl Volker13

Affiliation:

1. Department of Orthopaedic Surgery, University of Pittsburgh, Pittsburgh, Pennsylvania, USA.

2. Department of Orthopaedic Sports Medicine, Klinikum rechts der Isar, Technical University of Munich, Munich, Germany.

3. Department of Bioengineering, University of Pittsburgh, Pittsburgh, Pennsylvania, USA.

Abstract

Background: Many graft fixation techniques are utilized for full-thickness soft tissue quadriceps tendon autografts during anterior cruciate ligament reconstruction (ACLR). Purpose: To determine the tensile properties of all–soft tissue quadriceps tendon graft fixation using a tied-suture versus continuous-loop tape technique. It was hypothesized that the continuous-loop tape technique would have less cyclic elongation and greater ultimate load to failure and stiffness compared with a commonly used tied-suture technique. Study Design: Controlled laboratory study. Methods: Sixteen fresh-frozen human knee specimens were used to harvest a full-thickness all–soft tissue quadriceps tendon graft; half were secured using a Krackow suture technique with 2 braided sutures, and half were secured using a continuous-loop tape suspensory fixation button with a rip-stop stitch. Cyclic and permanent elongation, toe- and linear-region stiffness, and ultimate load were determined. Statistical analysis was performed at P <.05. Results: The tied-suture fixation group demonstrated significantly higher permanent elongation (11.7 ± 3.6 vs 4.2 ± 1.0 mm, P < .001) and cyclic elongation (5.9 ± 1.3 vs 2.0 ± 0.4 mm, P < .001) compared with the continuous-loop tape fixation group. There was a significantly higher linear-region stiffness with continuous-loop tape fixation compared with tied-suture fixation (98.8 ± 12.7 vs 85.5 ± 7.5 N/mm, P = .022). No significant difference in ultimate load between groups (517.1 ± 149.2 vs 465.6 ± 64.6 N) was found. The mode of failure was tendon pull-through for the continuous-loop tape group and suture breakage in the tied-suture group ( P < .001). Conclusion: Continuous-loop tape fixation is superior to tied-suture fixation in regard to elongation and stiffness for all–soft tissue quadriceps tendon grafts, but there was no significant difference in ultimate load. Clinical Relevance: Continuous-loop tape fixation of all–soft tissue quadriceps tendon grafts for ACLR is a valid technique with superior tensile properties.

Publisher

SAGE Publications

Subject

Orthopedics and Sports Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3