The Role of the Hip Capsule in Restoring Stability in the Initial Phase of Hip Distraction: An In Vivo Analysis

Author:

Mortensen Alexander J.1,Featherall Joseph1,Metz Allan K.1,Rosenthal Reece M.1,O’Neill Dillon C.1,Froerer Devin L.2,Khalil Ameen Z.1,Tomasevich Kelly M.1,Aoki Stephen K.1

Affiliation:

1. Department of Orthopaedics, University of Utah, Salt Lake City, Utah, USA

2. University of Utah School of Medicine, Salt Lake City, Utah, USA

Abstract

Background: The labral suction seal has been shown to provide the majority of resistance in the initial phase of hip distraction. However, the effect of an unrepaired interportal capsulotomy and capsular repair on the initial phase of hip distractive stability in vivo is not well understood. Purpose: To investigate the effect of capsular repair on the initial phase of distractive stability of hip joints in patients with femoroacetabular impingement (FAI) syndrome. Study Design: Controlled laboratory study. Methods: Patients undergoing primary hip arthroscopy for FAI between March and August 2020 were prospectively enrolled. Total joint space was measured on fluoroscopic images at the medial and lateral edges of the sourcil at 12.5-lb (5.7-kg) axial traction intervals (up to 100 lb [45.4 kg]) in 3 capsular states: (1) native capsule, (2) interportal capsulotomy, and (3) capsular repair. Distraction on anteroposterior radiographs was calculated as the difference between total joint space at each traction interval and baseline joint space at 0 lb, normalized to millimeters. The native, capsulotomy, and capsular repair states were compared using Wilcoxon signed-rank and McNemar tests. Results: Included were 36 hips in 35 patients. The median force required to distract ≥3 mm was 75 lb (34.0 kg; 95% CI, 70-80 lb [31.8-36.3 kg]) in both the native and capsular repair states ( P = .629), which was significantly greater than the median force required to distract ≥3 mm in the capsulotomy state (50 lb [22.7 kg]; 95% CI, 45-55 lb [20.4-24.9 kg]) ( P < .001). The most rapid rates of change in joint space were observed at the traction interval at which hips first achieved ≥3 mm of distraction (n = 33 hips; 92%). Conclusion: The traction force at which hips distracted ≥3 mm was 75 lb (34.0 kg) in both the native capsular and capsular repair states. Significantly less traction force (50 lb [22.7 kg]) distracted hips ≥3 mm in the capsulotomy state. Complete capsular closure after interportal capsulotomy resulted in restoration of initial distractive stability relative to the unrepaired capsulotomy state at time zero after primary hip arthroscopy. Clinical Relevance: This study provides surgeons with an improved understanding of the additional stability to the hip joint from capsular repair after hip arthroscopy for FAI syndrome.

Publisher

SAGE Publications

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3