The Biomechanical Consequences of Arthroscopic Hip Capsulotomy and Repair in Positions at Risk for Dislocation

Author:

Wach Amanda1,Mlynarek Ryan2,Maher Suzanne A.1,Kelly Bryan T.2,Ranawat Anil2

Affiliation:

1. Department of Biomechanics, Hospital for Special Surgery, New York, New York, USA.

2. Sports Medicine, Hospital for Special Surgery, New York, New York, USA.

Abstract

Background: The effect of interportal (IP) capsulotomy, short T-capsulotomy, and long T-capsulotomy, and their repairs, on resistance to anterior and posterior “at risk for dislocation” positions has not been quantified. Hypotheses: Our primary hypothesis was that an IP capsulotomy would have a minimal effect on hip resistive torque compared with both short and long T-capsulotomies in the at-risk dislocation positions. Our secondary hypothesis was that capsule repair would significantly increase hip resistive torque for all capsulotomies. Study Design Controlled laboratory study. Methods: We mounted 10 cadaveric hips on a biaxial test frame in an anterior dislocation high-risk position (20° of hip extension and external rotation) and posterior dislocation high-risk position (90° of hip flexion and internal rotation). An axial force of 100 N was applied to the intact hip while the femur was internally or externally rotated at 15° per second to a torque of 5 N·m. The rotatory position at 5 N·m was recorded and set as a target for each subsequent condition. Hips were then sequentially tested with IP, short T-, and long T-capsulotomies and with corresponding repairs randomized within each condition. Peak resistive torques were compared using generalized estimating equation modeling and post hoc Bonferroni-adjusted tests. Results: For the anterior position, the IP and long T-capsulotomies demonstrated significantly lower resistive torques compared with intact. For the posterior position, both the short and long T-capsulotomies resulted in significantly lower resistive torques compared with intact. Repairs for all 3 capsulotomy types were not significantly different from the intact condition at anterior and posterior positions. Conclusion: An IP incision resulted in a decrease in capsular resistive torque in the anterior but not the posterior at-risk dislocation position, in which direction only T-capsulotomies led to a significant decrease. All capsulotomy repair conditions resulted in hip resistive torques that were similar to the intact hip in both dislocation positions. Clinical Relevance Our results suggest that it is biomechanically advantageous to repair IP, short T-, and long T-capsulotomies, particularly for at-risk anterior dislocation positions.

Publisher

SAGE Publications

Subject

Orthopedics and Sports Medicine

Cited by 5 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3