Arthroscopic Rotator Cuff Repair Using the Undersurface Technique

Author:

Rubenis Imants1,Lam Patrick H.1,Murrell George A.C.1

Affiliation:

1. Orthopaedic Research Institute, St George Hospital Campus, University of New South Wales, Sydney, Australia.

Abstract

Background: Arthroscopic rotator cuff repair has traditionally been performed in the subacromial space from the bursal side of the tendon. The undersurface rotator cuff repair technique involves the arthroscope remaining in the glenohumeral joint, thus viewing the tendon from its undersurface during repair without a bursectomy or acromioplasty. Purpose: To compare the clinical and structural outcomes of undersurface rotator cuff repair with bursal-side repair. Study Design: Cohort study; Level of evidence, 3. Methods: A retrospective analysis of prospectively collected data was conducted on 2 cohorts of patients who had undergone arthroscopic rotator cuff repair with knotless suture anchors configured in a single-row formation using inverted mattress–style sutures from either the bursal side (n = 100) or undersurface (n = 165) of the supraspinatus tendon. Data were collected preoperatively, intraoperatively, and at 1 week, 6 weeks, 3 months, 6 months, and 2 years postoperatively. At each time point, patients completed a modified L’Insalata questionnaire to assess patient-ranked pain scores and were clinically examined using standardized tests. Ultrasound examination was performed at 6 months and 2 years to assess the integrity of the repair. Results: At 2 years postoperatively, patients in both cohorts had significantly less pain and less difficulty with overhead activities compared with preoperative levels ( P < .001). The type of repair performed (bursal or undersurface) did not affect the ability to perform overhead activities at 2 years. At 2 years, both groups also had similar retear rates (21% for bursal side, 23% for undersurface). The mean operative time for the arthroscopic rotator cuff repair was 32 minutes when performed from the bursal side and 20 minutes when performed from the undersurface ( P < .001). Conclusion: Arthroscopic rotator cuff repair, whether performed from the subacromial space or glenohumeral joint, resulted in decreased levels of pain and difficulty with overhead activities at 2 years. The major difference between the 2 techniques was operative time, with the undersurface technique being performed significantly faster than the bursal-side repair technique.

Publisher

SAGE Publications

Subject

Orthopedics and Sports Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3