Treatment of Acute Proximal Anterior Cruciate Ligament Tears—Part 1: Gap Formation and Stabilization Potential of Repair Techniques

Author:

Bachmaier Samuel1,DiFelice Gregory S.2,Sonnery-Cottet Bertrand3,Douoguih Wiemi A.4,Smith Patrick A.5,Pace Lee J.6,Ritter Daniel1,Wijdicks Coen A.1

Affiliation:

1. Department of Orthopedic Research, Arthrex, Munich, Germany.

2. Hospital for Special Surgery, New York, New York, USA.

3. Centre Orthopedique Santy, Lyon, France.

4. MedStar Washington Hospital Center, Washington, District of Columbia, USA.

5. University of Missouri, Columbia, Missouri, USA.

6. Connecticut Children’s Specialty Group, Hartford, Connecticut, USA.

Abstract

Background:Recently, there has been a resurgence of interest in primary repair of the anterior cruciate ligament (ACL), with fixation techniques evolving. However, to date, there have been no biomechanical studies comparing fixed to adjustable fixation repair techniques.Hypothesis:Adjustable ACL repair provides for improved stabilization compared with fixed techniques with respect to both gap formation and residual load-bearing capability.Study Design:Controlled laboratory study.Methods:A total of 4 different ACL repair techniques (n = 5 per group), including single– and double–cinch loop (CL) cortical button fixation as well as knotless single–suture anchor fixation, were tested using a porcine model. For adjustable single-CL loop fixation, additional preconditioning (10 cycles at 0.5 Hz) was performed. The force after fixation and the actuator displacement to achieve a time-zero preload of 10 N were measured for fixed techniques. Incrementally increasing cycling (1 mm/500 cycles) from 1 to 8 mm was performed for 4000 cycles at 0.75 Hz before pull to failure (50 mm/min). The final residual peak load and gap formation for each test block were analyzed as well as ultimate strength.Results:Knot tying of a single-CL over a button (mean ± SD, 0.66 ± 0.23 mm) and knotless anchor fixation (0.20 ± 0.12 mm) resulted in significant time-zero gaps ( P < .001) and significantly higher overall gap formation at reduced residual loading (analysis of covariance, P < .001) compared with both the double-CL loop and adjustable fixation techniques. The adjustable group showed the highest failure load and stiffness, at 305.7 N and 117.1 N/mm, respectively. The failure load of the knotted single-CL group was significantly reduced compared with all other groups ( P < .001).Conclusion:Adjustable single-CL cortical button fixation with intraoperative preconditioning optimized time-zero ACL tension and led to significantly improved stabilization and reduced gap formation, with the highest ultimate strength. Single-CL loop knot tying over the button and knotless anchor fixation resulted in time-zero gaps to achieve slight tension on the ACL and significantly higher gap formation at reduced load-bearing capability.Clinical Relevance:Although the clinical relevance of gap formation is uncertain, a biomechanical understanding of the stabilization potential of current ACL repair techniques is pertinent to the continued evolution of surgical approaches to enable better clinical outcomes.

Publisher

SAGE Publications

Subject

Orthopedics and Sports Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3