Effect of 3-Dimensional Versus Single-Plane Changes in Pelvic Dynamics on Range of Motion in Hips With Femoroacetabular Impingement: A Computer Simulation Analysis

Author:

Honda Hideki1,Kobayashi Naomi1,Kamono Emi1,Yukizawa Yohei1,Higashihira Shota2,Takagawa Shu1,Choe Hyonmin2,Ike Hiroyuki2,Tezuka Taro2,Inaba Yutaka2

Affiliation:

1. Department of Orthopaedic Surgery, Yokohama City University Medical Center, Yokohama, Japan.

2. Department of Orthopaedic Surgery, Graduate School of Medicine, Yokohama City University, Yokohama, Japan.

Abstract

Background: Femoroacetabular impingement (FAI) is primarily caused by bony impingement between the acetabulum and femoral neck during hip motion. Increasing posterior pelvic tilt improves hip range of motion in patients with FAI. Purpose: To use computer simulation analysis to compare the effects of 3-dimensional (3D) changes in pelvic tilt (sagittal tilt [St], axial rotation, and coronal tilt) with changes in a single plane (St), with the aim of improving range of motion in patients with FAI. Study Design: Controlled laboratory study. Methods: We evaluated 43 patients with FAI treated by arthroscopic cam resection. A 3D simulation was used to construct the following pelvic models: a 5° and 10° increase posteriorly in St (St5° and St10°) and a combined 5° change in St, axial rotation, and coronal tilt (Complex5°) from the baseline of the anterior pelvic plane. Improvements in maximum internal rotation (MIR) at 45°, 70°, and 90° of hip flexion and improvements in maximum flexion with no internal rotation were compared among the St5°, St10°, and Complex5° models. The pelvic models of each single-plane change of 5° and 10° were evaluated in the same simulation. Results: At 90° and 70°, there was a significant difference between the Complex5° and St10° models with respect to improvement in MIR ( P = .004 at 90° of flexion; P = .017 at 70° of flexion). There was no significant difference in MIR at 45° of flexion ( P = .71) or in maximum flexion ( P = .42). Conclusion: At 70° and 90° of hip flexion, a combined change in 3D pelvic alignment of 5° (ie, St, axial rotation, and coronal tilt) was more effective in improving hip MIR than a 10° change in St only. Clinical Relevance: Effective physical therapy for FAI should address pelvic motion in all 3 planes rather than in a single plane.

Publisher

SAGE Publications

Subject

Orthopedics and Sports Medicine

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3