Ability to Retension Knotless Suture Anchors: A Biomechanical Analysis of Simulated Bankart Lesions

Author:

LeVasseur Matthew R.1,Mancini Michael R.1,Williams Nicholas1,Obopilwe Elifho1,Cote Mark P.1,Coyner Katherine J.1,Arciero Robert A.1,Caldwell Paul E.23,Mazzocca Augustus D.14

Affiliation:

1. Department of Orthopaedic Surgery, University of Connecticut, Farmington, Connecticut, USA.

2. Tuckahoe Orthopaedics, Richmond, Virginia, USA.

3. Orthopaedic Research of Virginia, Richmond, Virginia, USA.

4. Department of Orthopaedic Surgery, Massachusetts General Hospital, Boston, Massachusetts, USA

Abstract

Background: Knotless suture anchors are gaining popularity in arthroscopic glenohumeral labral repairs. The ability to retension knotless designs after initial anchor placement has been reported; however, no studies have quantified this claim or investigated the biomechanical consequence of retensioning. Purpose/Hypothesis: To determine whether knotless and knotted suture anchors have biomechanical or anatomic differences with regard to labral repairs and to determine whether retensioning of knotless suture anchors affects capsular tension, labral height, and capsular shift. We hypothesized that retensioning of knotless anchors would result in improved capsular tension compared with conventional knotted suture anchors. Study Design: Controlled laboratory study. Methods: A total of 18 fresh-frozen cadaveric shoulders with a mean age of 56 years were dissected to the capsule and disarticulated at the humeral capsular insertion. The scapula was potted and placed in a custom shoulder simulator to tension the capsule via braided sutures localized to the anteroinferior glenohumeral ligament. Specimens were randomized into 3 groups: (1) Knotted (KT), (2) Knotless with end retensioning (KLend), and (3) Knotless with stepwise retensioning (KLstepwise). All repairs were completed using all-suture anchors placed at the 5-, 4-, and 3-o’clock positions. KLstepwise was used to simulate an intraoperative technique. Resultant mean capsular tension under 5 mm of displacement (subfailure loading) was measured for each anchor placement and retensioning step. Labral height and capsular shift were measured using a MicroScribe digitizer. Results: The intact, defect, 1-anchor, 2-anchor, and 3-anchor tensions were not significantly different between the KT and KLend groups. For the latter, retensioning of all knotless anchors increased capsular tension by 2.1 N compared with its 3-anchor state, although this was not statistically significant ( P = .081). The KLstepwise group explored an alternative method to retension the capsule using knotless anchors, with similar final capsular tensions compared with the other groups. All repairs had similar improvements in capsulolabral height and superior capsular shift. Conclusion: Knotted and knotless suture anchors provided similar overall restorations in anteroinferior glenohumeral ligament tension. However, knotless devices were capable of small but statistically insignificant improvements in capsular tension with retensioning. Clinical Relevance: Retensioning of knotless anchors allows the surgeon to tighten regions of the glenohumeral capsule that remain lax after repair.

Publisher

SAGE Publications

Subject

Orthopedics and Sports Medicine

Cited by 3 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3