Do Rotation and Measurement Methods Affect Reliability of Anterior Cruciate Ligament Tunnel Position on 3D Reconstructed Computed Tomography?

Author:

Moon Hyun-Soo12,Choi Chong-Hyuk13,Jung Min13,Lee Dae-Young14,Chang Hsienhao2,Kim Sung-Hwan12

Affiliation:

1. Arthroscopy and Joint Research Institute, Yonsei University College of Medicine, Seoul, Republic of Korea.

2. Department of Orthopedic Surgery, Gangnam Severance Hospital, Yonsei University College of Medicine, Seoul, Republic of Korea.

3. Department of Orthopedic Surgery, Severance Hospital, Yonsei University College of Medicine, Seoul, Republic of Korea.

4. Department of Orthopedic Surgery, Saegil Hospital, Seoul, Republic of Korea.

Abstract

Background: The literature has seldom investigated the anterior cruciate ligament (ACL) tunnel position while considering the effect of rotation of 3-dimensional computed tomography (3D-CT) images during measurements. Hypothesis: We hypothesized that (1) measurement of the ACL tunnel position in the femur and tibia through use of 3D-CT is considerably influenced by rotation of the 3D model and (2) there exists a reliable measurement method for ACL tunnel position least affected by rotation. Study Design: Controlled laboratory study. Methods: The 3D-CT images of 30 randomly selected patients who underwent single-bundle ACL reconstruction were retrospectively reviewed. For femoral tunnel assessments, rectangular reference frames were used that involved the highest point of the intercondylar notch and outer margins of the lateral femoral condyle (method 1), the highest point of the intercondylar notch and outer margins of the lateral wall of the intercondylar notch (method 2), and the lowest point of the intercondylar notch and outer margins of the lateral femoral condyle (method 3). For tibial tunnel assessments, rectangular reference frames with the cortical outline at the articular surface of the tibia (method A) and the cortical outline of the proximal tibia (method B) were used. For both femoral and tibial assessments, the tunnel positions at 5°, 10°, and 15° of rotation of the 3D model were compared with that at a neutral position. Results: The values measured by methods 1 and 3 showed significant differences at greater than 5° of rotation compared with the value at the neutral position, whereas method 2 showed relatively consistent results. However, the values measured with both methods A and B showed significant differences at greater than 5° of rotation compared with the value at the neutral position. Conclusion: The tunnel position on 3D-CT images was significantly influenced by rotation during measurements. For femoral tunnel position, measurement with a reference frame using the lateral wall of the intercondylar notch (method 2) was the least affected by rotation, with relatively consistent results. Clinical Relevance: This study demonstrates that measurement using the lateral wall of the intercondylar notch might be a consistent and reliable method for evaluating the ACL femoral tunnel position considering the effect of 3D-CT image rotation during measurements. However, both methods to measure tibial tunnel position described in this study were similarly affected by rotation.

Publisher

SAGE Publications

Subject

Orthopedics and Sports Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3