Ultrasonographic Measurement of Elbow Varus Laxity With a Sequential Injury Model of the Lateral Collateral Ligament–Capsular Complex

Author:

Kwak Jae-Man12,Rotman Dani13,Lievano Jorge Rojas1,Fitzsimmons James S.1,O’Driscoll Shawn W.1

Affiliation:

1. Department of Orthopedic Surgery, Mayo Clinic, Rochester, Minnesota, USA.

2. Department of Orthopedic Surgery, Uijeongbu Eulji Medical Center, College of Medicine, Eulji University, Uijeongbu, Republic of Korea.

3. Division of Orthopaedic Surgery, Tel Aviv Sourasky Medical Center, Sackler Faculty of Medicine, Tel Aviv University, Tel Aviv, Israel.

Abstract

Background: There is no consensus how to determine the varus laxity due to the LCL injury using the ultrasonography. There is a risk of lateral collateral ligament injury during or after arthroscopic extensor carpi radialis brevis release for tennis elbow. The equator of the radial head has been suggested as a landmark for the safe zone to not increase this risk; however, the safe zone from the intra-articular space has not been established. Hypothesis: Increased elbow varus laxity due to lateral collateral ligament–capsular complex (LCL-cc) injury could be assessed reliably via ultrasound. Study Design: Descriptive laboratory study. Methods: Eight cadaveric elbows were evaluated using a custom-made machine allowing passive elbow flexion under gravity varus stress. The radiocapitellar joint (RCJ) space was measured via ultrasound at 30° and 90° of flexion during 4 stages: intact elbow (stage 0), release of the anterior one-third of the LCL-cc (stage 1), release of the anterior two-thirds (stage 2), and release of the entire LCL-cc (stage 3). Two observers conducted the measurements separately, and the mean RCJ space in the 3 LCL-cc injury models (stages 1-3) at both flexion angles was compared with that of the intact elbow (stage 0). We also compared the measurements at 30° versus 90° of flexion. Results: At 30° of elbow flexion, the RCJ space increased 2 mm between stages 0 and 2 (95% confidence interval [CI], 1-3 mm; P < .01) and 4 mm between stages 0 and 3 (95% CI, 2-5 mm; P < .01). At 90° of elbow flexion, the RCJ space increased 1 mm between stages 0 and 2 (95% CI, 1-2 mm; P < .01) and 2 mm between stages 0 and 3 (95% CI, 2-3 mm; P < .01). Conclusion: Elbow varus laxity under gravity stress can be reliably assessed via ultrasound by measuring the RCJ space. Clinical Relevance: Because ultrasonographic measurement of the RCJ space can distinguish the increasing varus laxity seen with release of two-thirds or more of the LCL-cc, the anterior one-third of the LCL-cc, based on the diameter of the radial head, can be considered the safe zone in arthroscopic extensor carpi radialis brevis release for tennis elbow.

Publisher

SAGE Publications

Subject

Orthopedics and Sports Medicine

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3