Reanalysis of the Posterior Oblique Ligament: Quantitative Anatomy, Radiographic Markers, and Biomechanical Properties

Author:

Casp Aaron J.1,Bryniarski Anna2,Brady Alex W.2,Fossum Bradley W.2,Godin Jonathan A.23

Affiliation:

1. University of Alabama at Birmingham, Birmingham, Alabama, USA.

2. Steadman Philippon Research Institute, Vail, Colorado, USA.

3. The Steadman Clinic, Vail, Colorado, USA.

Abstract

Background: The posterior oblique ligament (POL) is the largest structure of the posteromedial knee that is at risk of injury in conjunction with the medial collateral ligament (MCL). Its quantitative anatomy, biomechanical strength, and radiographic location have not been assessed in a single investigation. Purpose: To evaluate the 3-dimensional and radiographic anatomy of the posteromedial knee and the biomechanical strength of the POL. Study Design: Descriptive laboratory study. Methods: Ten nonpaired fresh-frozen cadaveric knees were dissected and medial structures were elevated off bone, leaving the POL. The anatomic locations of the related structures were recorded with a 3-dimensional coordinate measuring machine. Anteroposterior and lateral radiographs were taken with radiopaque pins inserted into the pertinent landmarks, and the distances between the collected structures were calculated. Each knee was then mounted to a dynamic tensile testing machine, and pull-to-failure testing was performed to record the ultimate tensile strength, stiffness, and failure mechanism. Results: The POL femoral attachment was a mean of 15.4 mm (95% CI, 13.9-16.8 mm) posterior and 6.6 mm (95% CI, 4.4-8.8 mm) proximal to the medial epicondyle. The tibial POL attachment center was a mean of 21.4 mm (95% CI, 18.1-24.6 mm) posterior and 2.2 mm (95% CI, 0.8-3.6 mm) distal to the center of the deep MCL tibial attachment and a mean of 28.6 mm (95% CI, 24.4-32.8 mm) posterior and 41.9 mm (95% CI, 36.8-47.0 mm) proximal to the center of the superficial MCL tibial attachment. On lateral radiographs, the femoral POL was a mean of 17.56 mm (95% CI, 14.83-21.95 mm) distal to the adductor tubercle and 17.32 mm (95% CI, 14.6-21.7 mm) posterosuperior to the medial epicondyle. On the tibial side, the center of the POL attachment was a mean of 4.97 mm (95% CI, 3.85-6.79 mm) distal to the joint line on anteroposterior radiographs and 6.34 mm (95% CI, 5.01-8.48 mm) distal to the tibial joint line on lateral radiographs, at the far posterior tibial aspect. The biomechanical pull-to-failure demonstrated a mean ultimate tensile strength of 225.2 ± 71.0 N and a mean stiffness of 32.2 ± 13.1 N. Conclusion: The anatomic and radiographic locations of the POL and its biomechanical properties were successfully recorded. Clinical Relevance: This information is useful to better understand POL anatomy and biomechanical properties as well as to clinically address an injury with repair or reconstruction.

Publisher

SAGE Publications

Subject

Orthopedics and Sports Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3