Radial Meniscal Tears Are Best Repaired by a Modified “Cross” Tie-Grip Suture Based on a Biomechanical Comparison of 4 Repair Techniques in a Porcine Model

Author:

Nakanishi Yuta1,Hoshino Yuichi1,Nagamune Kouki2,Yamamoto Tetsuya1,Nagai Kanto1,Araki Daisuke1,Kanzaki Noriyuki1,Matsushita Takehiko1,Kuroda Ryosuke1

Affiliation:

1. Department of Orthopaedic Surgery, Kobe University Graduate School of Medicine, Kobe, Japan.

2. Department of Human and Artificial Intelligent Systems, Graduate School of Engineering, University of Fukui, Fukui, Japan.

Abstract

Background: The tie-grip suture can fix radial tears more rigidly than simple conventional sutures. However, one shortcoming is the residual gap at the central margin of the tear. The tie-grip suture was modified to address this issue and named the “cross tie-grip suture.” Purpose/Hypothesis: The purpose of this study was to compare the suture stability and strength among 4 suturing techniques: the original tie-grip, cross tie-grip, and 2 conventional sutures (double horizontal and cross). It was hypothesized that the cross tie-grip suture would show the least displacement and resist the greatest maximum load. Study Design: Controlled laboratory study. Methods: A total of 40 fresh-frozen porcine knees were dissected to acquire 80 menisci; 20 menisci were tested in each suture group. A radial tear was created at the middle third of the meniscal body. Repair was performed with the following: original tie-grip, cross tie-grip, double horizontal, and cross sutures. The mechanical strength of sutured menisci was evaluated using a tensile testing machine. All menisci underwent submaximal loading and load to failure. The gap distance and ultimate failure load were compared using analysis of variance. The failure mode was recorded after load-to-failure testing. Results: Displacement after 500 cycles was significantly smaller in the cross tie-grip group (0.4 ± 0.3 mm) compared with the tie-grip (0.9 ± 0.6 mm), double horizontal (1.2 ± 0.7 mm), and cross suture groups (1.4 ± 0.6 mm) ( P < .05). The ultimate failure load was significantly greater in the cross tie-grip (154.9 ± 29.0 N) and tie-grip (145.2 ± 39.1 N) groups compared with the double horizontal (81.2 ± 19.9 N) and cross suture groups (87.3 ± 17.7 N) ( P < .05). Tissue failure was the most common mode of failure in all groups. Conclusion: Upon repair of radial meniscal tears, the cross tie-grip suture showed less displacement compared with that of the tie-grip, double horizontal, and cross sutures and demonstrated equivalent load to failure to that of the tie-grip suture at time zero. Clinical Relevance: The cross tie-grip suture provided high resistance to displacement after repair of radial tears and may be advantageous in healing for radial meniscal tears.

Publisher

SAGE Publications

Subject

Orthopedics and Sports Medicine

Cited by 21 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3