Comparison of the PROMIS and iHOT-12 in Determining Satisfaction Levels After Hip Arthroscopy for FAIS

Author:

Martin RobRoy L.1,Harris Joshua D.2ORCID,Ellis Thomas3,Kollmorgen Robert4

Affiliation:

1. Department of Physical Therapy, Rangos School of Health Sciences, Duquesne University, Pittsburgh, Pennsylvania, USA

2. Department of Orthopaedic Surgery, Houston Methodist, Houston, Texas, USA

3. Orthopedic One, Dublin, Ohio, USA

4. Department of Orthopedic Surgery, UCSF Fresno, Fresno, California, USA

Abstract

Background: The Patient-Reported Outcomes Measurement Information System (PROMIS) has not been fully evaluated for outcomes assessment after hip arthroscopy to correct femoroacetabular impingement syndrome (FAIS). Purpose/Hypothesis: The purpose of this study was to compare the accuracy of the PROMIS Physical Function (PF) and Pain Interference (PI) subscales with the 12-Item International Hip Outcome Tool (iHOT-12) to define patients with 3 unique substantial clinical benefit (SCB) scores—patients who reported ≥80%, ≥90%, and 100% satisfaction at 1 year after hip arthroscopy for FAIS. We hypothesized that the iHOT-12 would be more accurate than the PROMIS-PF and PROMIS-PI subscales in identifying these 3 patient groups. Study Design: Cohort study (diagnosis); Level of evidence, 2. Methods: We reviewed the records of patients who underwent hip arthroscopy for symptomatic FAIS at 3 centers from January 2019 through June 2021 and had 1-year clinical and radiographic follow-up data. Patients completed the iHOT-12, PROMIS-PF, and PROMIS-PI on initial assessment and at 1 year (±30 days) postoperatively. Postoperative satisfaction was reported on an 11-category scale with anchors defined as “0% satisfied” and “100% satisfied.” Receiver operator characteristic analysis was performed to determine the absolute SCB values for the iHOT-12 and PROMIS subscales that would most accurately identify those patients who reported ≥80%, ≥90%, and 100% satisfaction. Area under the curve (AUC) values and 95% CIs for the 3 instruments were compared. Results: Included were 163 patients (111 [68%] women and 52 [32%] men), with a mean age of 26.1 years. Corresponding absolute SCB scores for patients who reported ≥80%, ≥90%, and 100% satisfaction were as follows: iHOT-12, 68.4, 72.1, 74.7; PROMIS-PF, 45, 47.7, 49.9; and PROMIS-PI, 55.9, 52.4, 51.9. The AUC ranged between 0.67 and 0.82, with overlapping 95% CIs indicating a minimal difference in accuracy between the 3 instruments. Sensitivity and specificity values ranged between 0.61 and 0.82. Conclusion: The PROMIS-PF and PROMIS-PI subscales were as accurate as the iHOT-12 in defining absolute SCB scores for patients reporting ≥80%, ≥90%, and 100% satisfaction at 1-year follow-up after hip arthroscopy for FAIS.

Publisher

SAGE Publications

Subject

Orthopedics and Sports Medicine

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3