The “N+10 Rule” to Avoid Graft-Tunnel Mismatch in Bone–Patellar Tendon–Bone ACL Reconstruction Using Independent Femoral Tunnel Drilling

Author:

Graf Ryan M.1,Dart Scott E.1,MacLean Ian S.1,Barras Laurel A.1,Moran Thomas E.1,Werner Brian C.1,Gwathmey F. Winston1,Diduch David R.1,Miller Mark D.1

Affiliation:

1. University of Virginia Health System, Charlottesville, Virginia, USA

Abstract

Background: Graft-tunnel mismatch (GTM) is a common problem in anterior cruciate ligament (ACL) reconstruction (ACLR) using bone–patellar tendon–bone (BPTB) grafts. Hypothesis: Application of the “N+10 rule” in endoscopic ACLR with BPTB grafts will result in acceptable tibial tunnel length (TTL), minimizing GTM. Study Design: Controlled laboratory study. Methods: Endoscopic BPTB ACLR was conducted on the paired knees of 10 cadaveric specimens using 2 independent femoral tunnel drilling techniques—accessory anteromedial portal and flexible reamer. The graft bone blocks were trimmed to 10 × 20 mm, and the intertendinous distance (represented by “N”) between the bone blocks was measured. The N+10 rule was used to set the angle of the ACL tibial tunnel guide to the appropriate number of degrees for drilling. The amount of excursion or recession of the tibial bone plug in relation to the anterior tibial cortical aperture was measured in both flexion and extension. A GTM threshold of ±7.5 mm was set based on prior studies. Results: The mean BPTB ACL intertendinous distance was 47.5 ± 5.5 mm. The mean measured intra-articular distance was 27.2 ± 3 mm. Using the N+10 rule, the mean total (flexion plus extension) GTM was 4.3 ± 3.2 mm (GTM in flexion, 4.9 ± 3.6 mm; GTM in extension, 3.8 ± 3.5 mm). In 18 of 20 (90%) cadaveric knees, the mean total GTM fell within the ±7.5-mm threshold. When comparing the actual measured TTL to the calculated TTL, there was a mean difference of 5.4 ± 3.9 mm. When comparing femoral tunnel drilling techniques, the total GTM for the accessory anteromedial portal technique was 2.1 ± 3.7 mm, while the total GTM for the flexible reamer technique was 3.6 ± 5.4 mm ( P = .5). Conclusion: The N+10 rule resulted in an acceptable mean GTM in both flexion and extension. The mean difference between the measured versus calculated TTL using the N+10 rule was also acceptable. Clinical Relevance: The N+10 rule is a simple and effective intraoperative strategy for achieving desired TTL regardless of patient-specific factors to avoid excessive GTM in endoscopic BPTB ACLR using independent femoral tunnel drilling.

Publisher

SAGE Publications

Subject

Orthopedics and Sports Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3