Analysis and experimentation of variable gap magnetorheological transmission device driven by electromagnetic force

Author:

Gong Hang1ORCID,Huang Jin1

Affiliation:

1. Department of Mechanical Engineering, Chongqing University of Technology, Chongqing, People’s Republic of China

Abstract

To solve the problems of poor transmission performance and small torque regulation range of traditional MR device, a variable working gap MRF transmission device driven by electromagnetic force is proposed. The device uses electromagnetic force driving the squeeze disk to move axially to squeeze the MRF, thereby changing the number of working gaps and effective working thickness of the MRF to improve the transmission performance of the MR device. Based on the coil magnetization effect, the relationship between current, magnetic field intensity, and electromagnetic force is established. According to the driving characteristics of electromagnetic force and the rheological characteristics of MRF, a nonlinear function relationship between electromagnetic force and MRF working gap thickness and working volume is derived. Using the finite element method, a theoretical analysis of the magnetic circuit design, magnetic field distribution and temperature change profile in different parts of MRF device with different currents was conducted, the MRF torque transfer equations were deduced and calculated, and experimentally verified the correctness of the theoretical equations. Finally, the transmission performance of the variable working gap MRF transmission device is tested through the established testing system. Results show that, the required squeeze force is 6.65 kN when the MRF thickness reaches 1 mm in both working gaps. As the current increases from 0.5 to 3.0 A, the electromagnetic force increases from 0.65 to 6.77 kN, with an increase of 972.3%, the average temperature of the MRF in working gap I increases from 25.2°C to 71.2°C and the MRF in working gap II increases from 23.5°C to 48.3°C. When the current is 1.5 A, the MRF in the working gap I reaches magnetic saturation, continue to increase the current to 3.0 A, the MRF thickness in both working gaps is 1 mm, and the MR device transmits torque reach 376.6 N·m, which is 72.3% higher than that of the traditional MR device.

Funder

National Natural Science Foundation of China

Publisher

SAGE Publications

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3