Gas flow between coaxial tubes: Impedance to gas flow in an endotracheal tube increases with a catheter within

Author:

Magee Patrick T1

Affiliation:

1. Anaesthesia, Royal United Hospital Bath, UK

Abstract

The insertion of a suction catheter or a bronchoscope down an endotracheal tube increases the resistance to gas flow down the tube. The extent to which this occurs depends on the relative diameters of the endotracheal tube and the coaxially introduced catheter. This study utilises a laboratory model to quantify this effect, using a steady flow down an annulus between two tubes whose long axes lie co-axially. Two diameters of an endotracheal tube were modelled to represent flow down adult and neonatal endotracheal tubes; these were of internal diameter (do) 6.3 mm and 3.2 mm, and of length (L) 555 mm. A steady flow of air was generated to pass through the model ‘endotracheal’ tube. Flowrates were calculated to give Re of approximately 5000 for the larger endotracheal tube, and of approximately 1300 for the smaller. These values correspond to clinically appropriate flowrates in adult and neonatal patients, respectively. The pressure drop ΔPo down the endotracheal tube was measured initially without any obstruction, using a calibrated pressure transducer. Catheters of diameter (di) 0.8 mm, 1.6 mm, and 3.2 mm were introduced into the larger diameter endotracheal tube, while catheters of 0.8 mm and 1.6 mm were introduced into the smaller one, and flow was restored to its original value. The pressure drops ΔP down the endotracheal tubes were measured with the catheters introduced a length ‘x’ into the tube, to x = L/2 and to x = L. Results are compared with a theoretical calculation on the basis of laminar flow for concentric tubes. If a sampling tube or suction catheter is used down the length of an infant’s endotracheal tube, the results show that for most values of do/di, there is a significant rise in ΔP/ΔPo. Where a flexible bronchoscope is used down an endotracheal tube or a telescope down a rigid bronchoscope, the value of ΔP/ΔPo may also increase unacceptably where do/di is low. The results show that for equal do/di, and equal values of x, ΔP/ΔPo are lower for higher values of Re than for lower; and that for lower values of Re there is a more rapid increase in ΔP/ΔPo as x increases, than for higher Re, especially at low values of do/di. This result quantifiably confirms clinical experience; that care must be taken in introducing a catheter down a neonatal endotracheal tube. Deviation of these results from the theoretical calculation is less for the smaller Reynolds numbers and smaller values of do/di, because under these conditions the flow is more likely to be laminar, with a greater degree of concentricity.

Publisher

SAGE Publications

Subject

Mechanical Engineering,General Medicine

Cited by 3 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3