Stability of femoral neck fracture fixation: A finite element analysis

Author:

Samsami Shabnam12,Augat Peter13,Rouhi Gholamreza4ORCID

Affiliation:

1. Institute for Biomechanics, Trauma Center Murnau, Murnau, Germany

2. Faculty of Medicine, Ludwig Maximilian University of Munich (LMU), Munich, Germany

3. Institute for Biomechanics, Paracelsus Private Medical University, Salzburg, Austria

4. Faculty of Biomedical Engineering, Amirkabir University of Technology, Tehran, Iran

Abstract

Femoral neck fractures represent a relatively uncommon injury in the non-elderly population often resulting from high-energy trauma. Clinical outcome in these patients can be improved by optimizing surgical procedures and selecting appropriate fixation methods. The aim of this study was to develop a numerical fracture model to investigate the influence of critical mechanical factors on the stability of fixation methods for femoral neck fractures. The mechanical stability of fracture fixation was assessed through employing finite element models and simulating progressive consolidation of the fracture for a vertical femoral neck fracture (i.e. Pauwels type III in which the angle between the fracture line and the horizontal plane is greater than 70°). Mechanical performance was compared among three different fixation methods (cannulated screws, dynamic hip screw with de-rotational screw, and proximal femoral locking plate). Axial femoral head displacement varied from 2.3 mm for cannulated screws to 1.12 mm for proximal femoral locking plate, although dynamic hip screw with de-rotational screw indicated a value of 0.94 mm. Considering a consolidated fracture and full weight-bearing load case, average displacements of fracture fragments were obtained of about 1.5, 3 and 70 µm for dynamic hip screw with de-rotational screw, proximal femoral locking plate and cannulated screws methods, respectively. In terms of interfragmentary movements at the fracture site, outcomes of this study demonstrated that, in agreement with our previous experimental research, the dynamic hip screw with de-rotational screw implant is a more effective choice than cannulated screws and proximal femoral locking plate techniques for vertical femoral neck fractures in young patients. Thus, one may conclude that the use of dynamic hip screw with de-rotational screw, particularly during the early stages of bone healing, could provide suitable mechanical environments that facilitate direct bone formation and shorter healing times.

Publisher

SAGE Publications

Subject

Mechanical Engineering,General Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3