Mechanical and numerical characterization of ceramic femoral components for hip resurfacing arthroplasty

Author:

Vogel Danny1ORCID,Liebelt Martin2,Kalkowsky Florian1,Oberbach Thomas2,Delfosse Daniel3,Bader Rainer1

Affiliation:

1. Biomechanics and Implant Technology Research Laboratory, Department of Orthopaedics, University Medicine Rostock, Rostock, Germany

2. Mathys Orthopaedie GmbH, Moersdorf, Germany

3. Mathys AG Bettlach, Bettlach, Switzerland

Abstract

Hip resurfacing arthroplasty may have distinct advantages for young and active patients, but large metal-on-metal bearings can be associated with increased wear, adverse tissue reactions and higher rate of implant loosening. Ceramic wear couples are a commonly used alternative to metals and therefore might be an alternative for hip resurfacing arthroplastys. The aim of this study was to evaluate the mechanical strength of femoral components made of an alumina-toughened zirconia composite by means of experimental testing and finite element analysis. For the mechanical characterization, ceramic femoral components (Ø: 48 mm) were tested under compression loading experimentally until fracture occurred or a maximum load of 85 kN was obtained. The femoral components were either loaded against a ceramic cup or a copper ring (outer diameter Ø: 7.0 mm). In addition, the complex geometry of the ceramic femoral component was simplified, and only the stem was loaded in a cantilever test until fracture. In addition, the fracture tests were numerically simulated to investigate the influence of additional loading conditions and geometric parameters, which were not experimentally tested. The experimental data were used for validation of the finite element analysis. None of the tested ceramic femoral components fractured at a compression load of 85 kN when they were loaded against a ceramic cup at an inclination angle of 45°. When the femoral components were loaded against a copper ring, the femoral components fractured at 29.9 kN at a testing angle of 45°. The fracture load was reduced when an angle of 30° and increased when an angle of 60° was simulated. Using an experimental cantilever test, the stem of the femoral component fractured at 1124.0 N. When the stem length was increased or the diameter was reduced by 10% in the finite element analysis, the fracture load was reduced. Decreasing the length or increasing the diameter led to an increase of the fracture load. The strongest influence was found for the reduction of the transition radius of the stem, with a decrease of the fracture load up to 27.2%. The analyzed femoral components made of alumina-toughened zirconia (ATZ) showed sufficient mechanical capability to withstand high loadings during unfavorable loading conditions. However, further biomechanical and tribological investigations are required before clinical application.

Funder

Mathys Orthopaedie GmbH

Publisher

SAGE Publications

Subject

Mechanical Engineering,General Medicine

Cited by 5 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3