Abstract

Physiological outflow boundary conditions are necessary to carry out computational fluid dynamics simulations that reliably represent the blood flow through arteries. When dealing with complex three-dimensional trees of small arteries, and therefore with multiple outlets, the robustness and speed of convergence are also important. This study derives physiological outflow boundary conditions for cases in which the physiological values at those outlets are not known (neither in vivo measurements nor literature-based values are available) and in which the tree exhibits symmetry to some extent. The inputs of the methodology are the three-dimensional domain and the flow rate waveform and the systolic and diastolic pressures at the inlet. The derived physiological outflow boundary conditions, which are a physiological pressure waveform for each outlet, are based on the results of a zero-dimensional model simulation. The methodology assumes symmetrical branching and is able to tackle the flow distribution problem when the domain outlets are at branches with a different number of upstream bifurcations. The methodology is applied to a group of patient-specific arteries in the liver. The methodology is considered to be valid because the pulsatile computational fluid dynamics simulation with the inflow flow rate waveform (input of the methodology) and the derived outflow boundary conditions lead to physiological results, that is, the resulting systolic and diastolic pressures at the inlet match the inputs of the methodology, and the flow split is also physiological.

Publisher

SAGE Publications

Subject

Mechanical Engineering,General Medicine

Cited by 11 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3