Abstract

Composite coatings consisting of fluorapatite mixed with 20 wt% yttria (3 mol%) stabilized cubic phase zirconia (c-ZrO2, 3Y-TZP) or 20 wt% alumina (α-Al2O3) were deposited on Ti6Al4V substrates using a Nd:YAG laser cladding system. The interface morphology, phase composition, micro-hardness and biological properties of the two coatings were examined and compared. The results showed that the fluorapatite/Al2O3 specimen underwent a greater inter-diffusion at the interface between the coating layer and the transition layer than the fluorapatite/ZrO2 specimen. During the cladding process, the ZrO2 and Al2O3 components of the coating were completely decomposed or underwent phase transformation. In addition, the fluorapatite was partially decomposed. For both specimens, the coating layers contained fluorapatite, CaF2 and CaTiO3 phases. The coating layer of the fluorapatite/ZrO2 specimen additionally contained TTCP, CaO, CaZrO3 and m-ZrO2 (monoclinic phase), while that of the fluorapatite/Al2O3 specimen contained β-TCP, CaAl2O4 and θ-Al2O3. The average micro-hardness of the fluorapatite/ZrO2 coating layer (1300 HV) was approximately 200 HV higher than that of the fluorapatite/Al2O3 coating layer (1100 HV). Both specimens generated dense bone-like apatite following immersion in simulated body fluid for 3 days. In other words, both specimens had a good in vitro bioactivity. However, the fluorapatite/ZrO2 specimen showed a better initial attachment and spread of osteoblast-like osteosarcoma MG63 cells than the fluorapatite/Al2O3 specimen in in vitro biocompatibility tests performed for 24 h.

Funder

Ministry of Science and Technology of the Republic of China

Chimei Foundation Hospital, Republic of China

Publisher

SAGE Publications

Subject

Mechanical Engineering,General Medicine

Cited by 3 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3