A robotic chewing simulator supplying six-axis mandibular motion, high occlusal force, and a saliva environment for denture tests

Author:

Qin Wenlong1ORCID,Cong Ming1,Liu Dong1,Ren Xiang2

Affiliation:

1. School of Mechanical Engineering, Dalian University of Technology, Dalian, China

2. College of Stomatology, Dalian Medical University, Dalian, China

Abstract

Six-axis motion is essential for the evaluation of the wear failure modes of dental prostheses with complete teeth morphologies, and a high occlusal force capacity is vital for static clenching and dynamic bruxism. Additionally, the saliva environment influences abrasive particles and crack growth. The present research was aimed at the development of a six-axis masticatory and saliva simulator with these capacities. The masticatory simulator was designed based on a six-axis parallel mechanism, and the saliva simulator consisted of a saliva circuit and a temperature control loop. A control system of the masticatory and saliva simulators was constructed. The operating interface includes a centric occlusal position search, a static test, a dynamic test, a saliva supply, and data reporting. The motion and force performances of the masticatory simulator were evaluated. The flow rate and temperature change of the saliva simulator were calculated. For the occlusal position-searching, the driving amplitude is linear with the moving variables during minor one-axis motion. For the static tests, the force capacity of the driving chain is 3540 N, while for the dynamic tests, the force capacity is 1390 N. The flow rate of the saliva is 0.18–51.84 mL/min, and the saliva can effectively wet the prosthesis without the risk of overflow. Moreover, the saliva temperature can increase from room temperature (23°C) to body temperature (37°C) in about 6 min. The proposed DUT-2 simulator with six-axis motion, high force, and a salvia environment provides an in vitro testing approach to validate numerical simulation results and explain the clinical failure modes of prostheses. The centric occlusal position-searching, static tests, and dynamic tests could therefore be executed using a single testing machine. Moreover, the proposed device is more compact than previously reported six-axis masticatory simulators, including the Bristol simulator and DUT-1 simulator.

Funder

National Natural Science Foundation of China

Publisher

SAGE Publications

Subject

Mechanical Engineering,General Medicine

Cited by 6 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3