Comparison of rigid and semi-rigid instrumentation under acute load on vertebrae treated with posterior lumbar interbody fusion/transforaminal lumbar interbody fusion procedures: An experimental study

Author:

Önen Mehmet Reşid1,Başgül Cemile2,Yılmaz İlhan1,Özkaya Mustafa3,Demir Teyfik2,Naderi Sait1

Affiliation:

1. Department of Neurosurgery, Ümraniye Training and Research Hospital, Istanbul, Turkey

2. Department of Mechanical Engineering, TOBB University of Economics and Technology, Ankara, Turkey

3. Department of Mechanical Engineering, KTO Karatay University, Konya, Turkey

Abstract

Rigid and semi-rigid fixations are investigated several times in order to compare their biomechanical stability. Interbody fusion techniques are also preferable for maintaining the sagittal balance by protecting the disk height. In this study, the biomechanical comparison of semi-rigid and rigid fixations with posterior lumbar interbody fusion or transforaminal lumbar interbody fusion procedures is conducted under trauma. There were four different test groups to analyze the effect of acute load on treated ovine vertebrae. First and second groups were fixed with polyetheretherketone rods and transforaminal lumbar interbody fusion and posterior lumbar interbody fusion cages, respectively. Third and fourth groups were fixed with titanium rods and posterior lumbar interbody fusion and transforaminal lumbar interbody fusion cages, respectively. The drop tests were conducted with 7 kg weight. There were six samples in each group so the drop test repeated 24 times in total. The test samples were photographed and X-rayed (laterally and anteroposteriorly) before and after drop test. Two fractures were observed on group 1. Conversely, there were no fractures observed for group 2. There were no anterior element fractures for both groups 1 and 2. However, one fracture seen on group 3 was anterior element fracture, whereas the other three were posterior element fractures. All three fractures were anterior element fractures for group 4. Treated vertebrae with polyetheretherketone rods and posterior lumbar interbody fusion cages showed the best durability to the drop tests among the groups. Semi-rigid fixation gave better results than rigid fixation according to failed segments. Posterior lumbar interbody fusion cages seem to be better option for semi-rigid fixation, however mentioned surgical disadvantages must be considered.

Publisher

SAGE Publications

Subject

Mechanical Engineering,General Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3