An instrumented palpation sensor, designed for measuring the dynamic modulus of tissue in vivo, has been developed and trialled on ex vivo whole prostate glands. The sensor consists of a flexible membrane sensor/actuator with an embedded strain gauge and is actuated using a dynamically varying airflow at frequencies of 1 and 5 Hz. The device was calibrated using an indentation stiffness measurement rig and gelatine samples with a range of static modulus similar to that reported in the literature for prostate tissue. The glands were removed from patients with diagnosed prostate cancer scheduled for radical prostatectomy, and the stiffness was measured within 30 min of surgical removal. Each prostate was later examined histologically in a column immediately below each indentation point and graded into one of the four groups; normal, benign prostatic hyperplasia, cancerous and mixed cancer and benign prostatic hyperplasia. In total, 11 prostates were assessed using multiple point probing, and the complex modulus at 1 and 5 Hz was calculated on a point-by-point basis. The device yielded values of quasi-static modulus of 15 ± 0.5 kPa and dynamic modulus of 20 ± 0.5 kPa for whole prostates, and a sensitivity of up to 80% with slightly lower specificity was achieved on diagnosis of prostate cancer using a combination of mechanical measures. This assessment did not take into account some obvious factors such as edge effects, overlap and clinical significance of the cancer, all of which would improve performance. The device, as currently configured, is immediately deployable in vivo. A number of improvements are also identified which could improve the sensitivity and specificity in future embodiments of the probe.

Publisher

SAGE Publications

Subject

Mechanical Engineering,General Medicine

Cited by 6 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3