A systematic review of variables used to assess clinically acceptable alignment of unilateral transtibial amputees in the literature

Author:

Tafti Nahid1,Hemmati Fatemeh1,Safari Reza2,Karimi Mohammad Taghi3,Farmani Farzad4,Khalaf Ali5,Mardani Mohammad Ali5

Affiliation:

1. Student Research Committee, University of Social Welfare and Rehabilitation Sciences, Tehran, Iran

2. Health and Social Care Research Centre, University of Derby, Derby, England

3. Rehabilitation Sciences Research Center, Shiraz University of Medical Sciences, Shiraz, Iran

4. Department of Orthotics and Prosthetics, Hamedan University of Medical Sciences, Hamedan, Iran

5. Department of Orthotics and Prosthetics, University of Social Welfare and Rehabilitation Sciences, Tehran, Iran

Abstract

Prosthetic alignment is a subjective concept which lacks reliability. The outcome responsiveness to prosthetic alignment quality could help to improve subjective and instrument assisted prosthetic alignment. This study was aimed to review variables used to assess clinically acceptable alignment in the literature. The search was done in some databases including: Google Scholar, PubMed, EBSCO, EMBASE, ISI Web of Knowledge and Scopus. The first selection criterion was based on abstracts and titles to address the research questions of interest. The American Academy of Orthotics and Prosthetics checklists were used for paper risk of bias assessment. A total of 25 studies were included in this study. Twenty-four studies revealed the critics of standing position or walking to locate clinically acceptable alignment, only one study measured outcomes in both situations. A total of 253 adults with transtibial amputations and mean age of 48.71 years participated in included studies. The confidence level of included studies was low to moderate, and before–after trial was the most common study design (n = 19). The joint angle, load line location with respect to joints and center of pressure–related parameters were reported as sensitive outcomes to prosthetic alignment quality in standing posture. The amount of forces at various parts of gait cycle and time of events were sensitive to prosthetic alignment quality during walking. Standing balance and posture and temporal parameters of walking could help to locate clinically acceptable alignment.

Funder

Iran National Science Foundation

Publisher

SAGE Publications

Subject

Mechanical Engineering,General Medicine

Cited by 5 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3