Abstract

Hip resurfacing is an attractive alternative to total hip replacement preserving bone and reducing dislocation risk. Recent metal-on-metal designs have caused failure due to metal wear debris. Ceramic implants may mitigate this risk. Temperature increase in periprosthetic bone during cementation can lead to osteonecrosis, while deformation of the component can affect joint lubrication and may increase wear through clamping. Both processes may lead to implant loosening. This study quantifies the temperature and deformation change in a novel ceramic hip resurfacing femoral component compared to a metal standard during cemented implantation in a fresh frozen cadaveric model. Study design and methods Eight femora were prepared from four fresh frozen cadavers. One surgeon experienced in hip resurfacing surgery (J.H.) prepared the femora by reaming. Four ceramic and four metal implants of equal and varying size were cemented in place. Bone and surface temperatures were taken using a probe in the periprosthetic bone and an infrared laser thermometer, respectively. Deformation was measured using a micrometre. Measurements were taken before implantation and every 5-min intervals up to 30 min. The average bone-temperature increment was lower for ceramic heads than for metal heads. Although this difference was not statistically significant, the average bone temperature incremental change in small sizes (42 and 46 mm) was higher than in the large sizes (48 and 50 mm). Most metal heads sustained bearing diameter change that was still near its peak value 30 min after implantation, whereas the ceramic heads suffered a lower diameter change and most of the samples recovered their original diameter 30 min after implantation. Both implants behave similarly, however, a lower temperature rise in bone was observed with ceramic heads. This may lower the risk for thermal damage on periprosthetic bone. The ceramic heads deformed less during surgical implantation. This was not significant.

Funder

MatOrtho

Publisher

SAGE Publications

Subject

Mechanical Engineering,General Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3