Abstract

Using external fixtures for bone deformity correction takes advantages of less soft tissue injury, better bone alignment and enhances strain development for bone formation on cutting section, which cause shorter healing time. Among these fixtures, Taylor spatial frame is widely used and includes two rings and six adjustable struts developing 6 degrees of freedom, making them very flexible for this type of application. The current study describes a method to optimize Taylor spatial frame pin-sizes currently chosen from the surgeon’s experiences. A three-dimensional model of femur was created from computed tomography images; segmentation of the medical images was made based on the Hounsfield unit (gray scale) in order to allocate adequate mechanical properties into cortical and trabecular bone sections. Both the cortical and trabecular sections were assumed to be isotropic and homogeneous. The diameter optimization of Taylor spatial frame’s half-pins was carried out by coupling genetic algorithm and finite element analysis. The finite element analysis was based on a static mechanical load corresponding to a standing person’s body weight. Finite element analysis results were validated with experimentally measured strains obtained from bone compression tests. A cost function, based on the developed bone stresses, was defined close to the Taylor spatial frame’s half-pins. The calculated cost function showed a decrease of over 33% from the initial half-pin selection by the surgeon and the genetic algorithm optimization. Consequently, the maximum stresses experienced by the bone in the connected location of the half-pins decreased from 121.4 MPa in the surgeon’s selection to 73.07 MPa as a result of the optimization process.

Publisher

SAGE Publications

Subject

Mechanical Engineering,General Medicine

Cited by 9 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3