Functional and structural effects of percutaneous edge-to-edge double-orifice repair under cardiac cycle in comparison with suture repair

Author:

Avanzini A1,Donzella G1,Libretti L1

Affiliation:

1. Department of Mechanical and Industrial Engineering, University of Brescia, Italy

Abstract

Percutaneous procedures for double-orifice mitral valve repair using the MitraClip® device (clip) have been recently introduced as new treatment options as alternatives to medical management and open-heart surgery, especially for patients with high estimated operative risk. Similarly to the open-heart surgical technique, where suturing is used, the clip creates a double-orifice configuration that not only improves the closing function of the valve, but also significantly modifies its behaviour, particularly in the diastolic phase. While several clinical trials have been conducted, and are ongoing, in order to assess the safety and effectiveness of this technique, a deeper knowledge of the structural and functional effects on the valve, and of the cyclic loads transmitted to the clip itself, would allow a comparison with other repair techniques, and could serve as a foundation for possible further optimization of the clip design. The effects of the MitraClip® device developed by Evalve Inc. were studied by means of a finite element model of the mitral valve, specifically developed to study the structural effects of the original, suture-based, edge-to-edge technique. A second model was developed in order to simulate the effects of a suture with similar extension from the leaflet edge in a direction to the annulus, in order to compare the two repair techniques. The mitral valve area and transvalvular pressure gradient predicted by the models for the clip and the suture are quite similar. Similar leaflet cyclic stresses, both in value and in location, were noted for the two mechanisms of linking the leaflets, while minor differences were found in the load transmitted to the suture and the clip, with slightly higher values for the clip. The model satisfactorily allowed functional parameters (valve area and transvalvular pressure gradient) and structural parameters (load, leaflet stress) to be determined. Overall, the structural effects of the clip and the suture are quite similar under the cyclic loading conditions imposed by the cardiac cycle.

Publisher

SAGE Publications

Subject

Mechanical Engineering,General Medicine

Cited by 11 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3