Abstract

Iatrogenic subtrochanteric fractures are rarely encountered after cannulated screw fixation of femoral neck fractures; however, when they do occur, there can be several complications. Many orthopedic surgeons have concerns about the potential for iatrogenic subtrochanteric fractures after screw fixation distal to the trochanter minor; therefore, some surgeons are typically reluctant to perform this procedure. This study focused on the risk of an iatrogenic subtrochanteric fracture after treating femoral neck fractures with cannulated screws. The main purpose of the study was to understand iatrogenic subtrochanteric fractures and evaluate the effects on these fractures of an inverted triangular–shaped configuration for placement of the cannulated screws. A femur bone with an femoral neck fracture at a 40° incline to the horizontal plane was generated along with a representation of a three-dimensional finite element model, and three inverted triangular–shaped configurations for placement of the cannulated screws were investigated using finite element analyses. Statistical results indicated that the occurrence risk of ISF increases when the screw is located distal to the trochanter minor. Moreover, the risk of occurrence of intertrochanteric fracture increases when the screw is located medial to the trochanter minor because of local concentrated stress on the surface of the screw canals. To avoid the vulnerability of the subtrochanteric region, it was found that proximal placement of the screws using the inverted triangular–shaped configuration could yield better results. In addition, the results of this study provide suggestions on improved screw configurations.

Publisher

SAGE Publications

Subject

Mechanical Engineering,General Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3