Biomechanical comparison of porcine mitral leaflets with porcine small intestinal submucosa extracellular matrix

Author:

Islamagič Lejla12ORCID,Tjørnild Marcell Juan12,Carlson Hanse Lisa12ORCID,Nygaard Jens Vinge3,Hasenkam John Michael12

Affiliation:

1. Department of Cardiothoracic and Vascular Surgery, Aarhus University Hospital, Aarhus, Denmark

2. Department of Clinical Medicine, Aarhus University, Aarhus, Denmark

3. Department of Biological and Chemical Engineering, Aarhus University, Aarhus, Denmark

Abstract

Porcine small intestinal submucosa extracellular matrix (SIS-ECM) used for cardiac valve repair has shown conflicting clinical outcomes with respect to calcification and failure. This may be related to differences in biomechanical properties of the material compared with the host site. The aim of this study was to compare the biomechanical properties of porcine mitral valve leaflets with SIS-ECM. Fresh porcine anterior and posterior mitral leaflet samples were cut radially and circumferentially. Similarly, 2- and 4-layered SIS-ECM were cut in orthogonal directions: length and width. Samples were subjected to a uniaxial tensile test or a dynamic mechanical analysis. Results show that the load of the porcine anterior circumferential leaflet was 39.5 N (2.4–48.5 N), which was significantly higher compared with the 2-layered length SIS-ECM which was 7.5 N (7–7.9 N), and the 4- layered length SIS-ECM which was 7.5 N (7.1–8.1 N) ( p < 0.001). The load of the posterior circumferential leaflet was 9.7 N (8.3–10.7 N), which is still significantly higher when compared with the two versions of SIS-ECM. The degree of anisotropy (i.e. the ratio between circumferential-radial and width-length properties) was higher for the anterior- (ratio: 19) and posterior leaflet (ratio: 6) than the 2-layered (ratio: 5.1) and 4-layered SIS-ECM (ratio: 1.9). Especially 2-layered SIS-ECM more closely resembles the posterior mitral leaflet than the anterior mitral leaflet tissue and would be more suitable as a repair material in this position. Additionally, the anisotropic properties of mitral leaflets and SIS-ECM underscore the importance of correct orientation of the implant to ensure optimal reconstruction.

Publisher

SAGE Publications

Subject

Mechanical Engineering,General Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3