Estimating the density of femoral head trabecular bone from hip fracture patients using computed tomography scan data

Author:

Vivanco Juan F12,Burgers Travis A3,García-Rodríguez Sylvana1,Crookshank Meghan45,Kunz Manuela5,MacIntyre Norma J5,Harrison Mark M56,Bryant J Tim45,Sellens Rick W45,Ploeg Heidi-Lynn1

Affiliation:

1. Department of Mechanical Engineering, University of Wisconsin–Madison, Madison, WI, USA

2. Facultad de Ingeniería y Ciencias, Universidad Adolfo Ibáñez, Viña del Mar, Chile

3. Van Andel Research Institute, Grand Rapids, MI, USA

4. Department of Mechanical and Materials Engineering, Queen’s University, Kingston, ON, Canada

5. Human Mobility Research Centre, Kingston General Hospital, Queen’s University, Kingston, ON, Canada

6. Department of Surgery, Queen’s University, Kingston, ON, Canada

Abstract

The purpose of this study was to compare computed tomography density ( ρCT) obtained using typical clinical computed tomography scan parameters to ash density ( ρash), for the prediction of densities of femoral head trabecular bone from hip fracture patients. An experimental study was conducted to investigate the relationships between ρash and ρCT and between each of these densities and ρbulk and ρdry. Seven human femoral heads from hip fracture patients were computed tomography–scanned ex vivo, and 76 cylindrical trabecular bone specimens were collected. Computed tomography density was computed from computed tomography images by using a calibration Hounsfield units–based equation, whereas ρbulk, ρdry and ρash were determined experimentally. A large variation was found in the mean Hounsfield units of the bone cores (HUcore) with a constant bias from ρCT to ρash of 42.5 mg/cm3. Computed tomography and ash densities were linearly correlated ( R2 = 0.55, p < 0.001). It was demonstrated that ρash provided a good estimate of ρbulk ( R2 = 0.78, p < 0.001) and is a strong predictor of ρdry ( R2 = 0.99, p < 0.001). In addition, the ρCT was linearly related to ρbulk ( R2 = 0.43, p < 0.001) and ρdry ( R2 = 0.56, p < 0.001). In conclusion, mineral density was an appropriate predictor of ρbulk and ρdry, and ρCT was not a surrogate for ρash. There were linear relationships between ρCT and physical densities; however, following the experimental protocols of this study to determine ρCT, considerable scatter was present in the ρCT relationships.

Publisher

SAGE Publications

Subject

Mechanical Engineering,General Medicine

Cited by 13 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3