Abstract

Radiostereometric analysis is a sophisticated radiographic technique with high measurement accuracy. In order to improve the accessibility of radiostereometric analysis for clinical use, a modified radiostereometric analysis procedure has been previously proposed that enables clinical radiographic views to be used for radiostereometric analysis. It has been successfully validated for its application to the hip wear study with the conventional bead–based radiostereometric analysis environment using computed radiography. In this study, we describe the implementation and validation of this technique for the knee study with the model-based radiostereometric analysis environment using digital radiography. A knee-joint phantom with 6 degrees of freedom was examined, and the bias and repeatability/reproducibility of the modified radiostereometric analysis approach were investigated following the newly updated ASTM recommendations. The bias parameters (mean ± 95% confidence interval) ranged from 0.008 ± 0.003 mm to 0.027 ± 0.006 mm for translation and from 0.014° ± 0.007° to 0.040° ± 0.020° for rotation. The repeatability standard deviation ranged from 0.004 to 0.020 mm for translation and from 0.005° to 0.015° for rotation. The 95% repeatability limit ranged from 0.011 to 0.055 mm for translation and from 0.014° to 0.041° for rotation. The reproducibility standard deviation ranged from 0.004 to 0.023 mm for translation and from 0.006° to 0.040° for rotation. The 95% reproducibility limit ranged from 0.012 to 0.063 mm for translation and from 0.016° to 0.112° for rotation. The modified procedure allows routine clinical radiographs to be used for radiostereometric analysis, which provides the possibility of adding quantitative measurements to current patient registries.

Funder

Natural Sciences and Engineering Research Council of Canada

Ministry of Research and Innovation

Publisher

SAGE Publications

Subject

Mechanical Engineering,General Medicine

Cited by 3 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

1. Phantom validation of a novel RSA-based impingement metric to assess component-on-component impingement risk;Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine;2024-03-22

2. Radiography;Imaging of the Knee;2023

3. Roentgen stereophotogrammetric analysis: still a very valuable tool in the orthopaedic research armamentarium;Bone & Joint Research;2022-04-01