Analysis of hip joint cross-shear under variable activities using a novel virtual joint model within Visual3D

Author:

Layton Robin B1ORCID,Messenger Neil2,Stewart Todd D1ORCID

Affiliation:

1. Institute of Medical Biological Engineering, University of Leeds, Leeds, UK

2. Faculty of Biomedical Sciences, University of Leeds, Leeds, UK

Abstract

Cross-shear forces occur between bearing surfaces at the hip and have been identified as a key contributor to prosthesis wear. Understanding the variation in relative motion paths between both individuals and activities, is a possible explanation for increased revision rates for younger patients and could assist in improved pre-clinical testing regimes. Additionally, there is little information for the pre-clinical testing of cartilage substitution therapies for younger more active individuals. The calculation of motion paths has previously relied on computational modelling software which can be complex and time-consuming. The aim of this study was to determine whether the motion paths calculations could be integrated into gait analysis software to improve batch processing, reduce analysis time and ultimately improve the efficiency of the analysis of cross-shear variation for a broader range of activities. A novel Virtual Joint model was developed within Visual3D for calculating motion paths. This model was compared to previous computational methods and found to provide a competitive solution for cross shear analysis (accuracy <0.01 mm error between methods). The virtual hip model was subsequently applied to 13 common activities to investigate local aspect ratio’s, velocities and accelerations. Surprisingly walking produced the harshest cross shear motion paths in subjects. Within walking, of additional interest was that the localised change in acceleration for subjects was six times greater compared to the same point on an equivalent smoothed simulator cycle. The Virtual hip developed in Visual 3D provides a time saving technique for visualising and processing large data sets directly from motion files. The authors postulate that rather than focussing on a generalised smoothed cross-shear model that pre-clinical testing of more delicate structures should consider localised changes in acceleration as these may be more important in the assessment of cartilage substitutes sensitive to shear.

Funder

engineering and physical sciences research council

Publisher

SAGE Publications

Subject

Mechanical Engineering,General Medicine

Cited by 5 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3