Computational analysis of the effects of interprosthetic distance on normal and reduced cortical thickness femur models

Author:

Güngörürler Musa1ORCID,Gürsan Onur2,Havıtçıoğlu Hasan2

Affiliation:

1. Department of Biomechanics, School of Medicine Health Science Institute, Dokuz Eylul University, Izmir, Turkey

2. Department of Orthopaedics and Traumatology, Dokuz Eylul University, Izmir, Turkey

Abstract

Distal femoral fractures associated with the femoral stem in a well-fixed hip arthroplasty pose a risk of an interprosthetic fracture, the treatment of which is known as difficult. To effectively prevent and treat IP fractures, biomechanical effects must be demonstrated. We defined eight variations of the interprosthetic distance ranging from 48 mm overlap to 128 mm gap. Femoral geometries with normal and reduced cortical thickness were modeled to evaluate the effects of cortical thickness. In addition to the intact model, a total of 16 finite element models were analyzed under physiological boundary conditions. Maximum and minimum principal strains on the lateral and medial cortex surfaces were always found to be greater in models with reduced cortical thickness than in normal femurs. The model with 48 mm overlapping interprosthetic distance produced the least peak strain and the model with 16 mm interprosthetic gap produced the greatest strain with both normal and reduced cortical thickness. The screw holes produced local strain concentrations and increased the peak strains on the cortex surfaces, especially close to the stem tip. Statistically, a significant correlation ( R2 = 0.9483) was found between strain shielding and interprosthetic distance. Axial stiffness, interfragmentary shear motion, and maximum von-Mises stress on the distal plate showed a high correlation with the interprosthetic distance. It was concluded that the overlapping structures are superior to other fixations we analyzed in that they offer better mechanical stability and eliminates the local strain concentrations.

Publisher

SAGE Publications

Subject

Mechanical Engineering,General Medicine

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3