A biomechanical comparison of posterior fixation approaches in lumbar fusion using computed tomography based lumbosacral spine modelling

Author:

Ramakrishna Vivek AS123ORCID,Chamoli Uphar24,Larosa Alessandro G4,Mukhopadhyay Subhas C3,Gangadhara Prusty B1,Diwan Ashish D25

Affiliation:

1. School of Mechanical and Manufacturing Engineering, University of New South Wales, Sydney, Kensington, NSW, Australia

2. Spine Labs, St. George & Sutherland Clinical School, University of New South Wales, Sydney, NSW, Australia

3. School of Engineering, Faculty of Science and Engineering, Macquarie University, Sydney, NSW, Australia

4. School of Biomedical Engineering, Faculty of Engineering and Information Technology, University of Technology Sydney, Ultimo, NSW, Australia

5. Spine Service, Department of Orthopaedic Surgery, St. George Hospital Campus, Kogarah, NSW, Australia

Abstract

Extreme lateral interbody fusion (XLIF) may be performed with a standalone interbody cage, or with the addition of unilateral or bilateral pedicle screws; however, decisions regarding supplemental fixation are predominantly based on clinical indicators. This study examines the impact of posterior supplemental fixation on facet micromotions, cage loads and load-patterns at adjacent levels in a L4-L5 XLIF at early and late fusion stages. CT data from an asymptomatic subject were segmented into anatomical regions and digitally stitched into a surface mesh of the lumbosacral spine (L1-S1). The interbody cage and posterior instrumentation (unilateral and bilateral) were inserted at L4-L5. The volumetric mesh was imported into finite element software for pre-processing, running nonlinear static solves and post-processing. Loads and micromotions at the index-level facets reduced commensurately with the extent of posterior fixation accompanying the XLIF, while load-pattern changes observed at adjacent facets may be anatomically dependent. In flexion at partial fusion, compressive stress on the cage reduced by 54% and 72% in unilateral and bilateral models respectively; in extension the reductions were 58% and 75% compared to standalone XLIF. A similar pattern was observed at full fusion. Unilateral fixation provided similar stability compared to bilateral, however there was a reduction in cage stress-risers with the bilateral instrumentation. No changes were found at adjacent discs. Posterior supplemental fixation alters biomechanics at the index and adjacent levels in a manner that warrants consideration alongside clinical information. Unilateral instrumentation is a more efficient option where the stability requirements and subsidence risk are not excessive.

Publisher

SAGE Publications

Subject

Mechanical Engineering,General Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3