Affiliation:
1. Department of Biomedical Engineering, Science and Research Branch, Islamic Azad University, Tehran, Iran
2. Faculty of Biomedical Engineering, Amirkabir University of Technology, Tehran, Iran
3. Iranian Tissue Bank and Research Center, Tehran University of Medical Sciences, Tehran, Iran
4. Department of Orthopedic, Tehran University of Medical Sciences, Tehran, Iran
Abstract
The goal of this study was to investigate two commonly used methods of fixation of distal metaphyseal tibia fractures, plating and nailing as well as the less frequently employed nailing with Poller screws, from a biomechanical perspective. Despite numerous studies, the best method to repair fractures of tibia the remains up for of debate. This study includes an in vitro experimental phase on human cadaveric tibias followed by a finite element analysis. In the experimental phase, under partial weight-bearing axial loading, the axial stiffness of the bone-implant construct and interfragmentary movements for each of the fixation methods, bone-plate, bone-nail, and bone-nail-Poller screw, were measured and compared with each other. Shear interfragmentary movement and stress distribution in the bone-implant construct for the three mentioned fixation methods were also determined from FE models and compared with each other. Results of in vitro experiments, i.e., the exertion of axial loading on the tibia-plate, tibia-nail, and tibia-nail-Poller screw, showed that utilization of tibia-nail and tibia-nail-Poller screw led to a stiffer bone-implant construct, and consequently, lower interfragmentary movement, compared to the tibia-plate construct ( p values for tibia-nail and tibia-nail-Poller screw, and for both axial stiffness and interfragmentary movement, compared to those of tibia-plate construct, were less than 0.05). Numerical analyses showed that nailing produced less undesirable shear interfragmentary movement, compared to the plating, and application of a Poller screw decreased the shear movements, compared to tibia-nail. Furthermore, using the finite element analysis, maximum von Mises stress of adding a screw in tibia-nail, tibia-plate, and tibia-nail-Poller screw, was found to be: 51.5, 78.6, and 60.5 MPa, respectively. The results of this study suggested that from a biomechanical standpoint, nailing both with and without a Poller screw is superior to plating for the treatment of distal tibia fractures.
Subject
Mechanical Engineering,General Medicine
Cited by
10 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献