Plate fixation of periprosthetic femur fractures: What happens to the cement mantle?

Author:

Konstantinidis Lukas1,Schmidt Benjamin2,Bernstein Anke1,Hirschmüller Anja1,Schröter Steffen3,Südkamp Norbert Paul1,Helwig Peter4

Affiliation:

1. Clinic for Orthopaedics and Traumatology, Albert Ludwigs University of Freiburg, Freiburg im Breisgau, Germany

2. Clinic for Anesthesiology and Intensive Care Medicine, University Hospital Leipzig, Leipzig, Germany

3. Department of Traumatology and Reconstructive Surgery, BG Trauma Center Tübingen, Eberhard Karls University Tübingen, Tübingen, Germany

4. Clinic for orthopedics and traumatology, Clinic Heidenheim, Heidenheim, Germany

Abstract

Osteosynthesis of periprosthetic femur fractures by screw fixation around the implanted prosthetic stem is currently regarded as the biomechanically superior option compared with cerclage. The aim of this biomechanical study was damage analysis of the cement mantle after revision screw insertion. A prosthetic stem (Bicontact) was implanted in 20 cadaveric femora in cemented technique. A locking compression plate (Synthes) was then applied to the lateral femur at the level of the prosthetic stem. The method of plate fixation to the femur was assigned randomly to three groups: bicortical non-locking screws, monocortical locking screws, and bicortical locking screws. This was followed by applying a fluctuating axial load (2100 N, 0.5 Hz) for 20,000 cycles. After testing, macroscopic and microscopic evaluations of the cement mantle were conducted. Cracks formed in the cement mantle in 14% of the 80 screw holes. The type of screw (bicortical or monocortical; locking or non-locking) had no significant effect on the number of cracks (p = 0.52). The relationship between manifestation of crack damage and cement mantle thickness was not significant (p = 0.36), whereas the relationship between crack formation and screw position was significant (p = 0.019). Those screws whose circumference was only partially within the cement mantle yielded a significantly lower number of cracks compared with screws positioned completely within the cement mantle or even touching the prosthetic stem. In order to reduce the incidence of crack formation in the cement mantle during plate osteosynthesis of periprosthetic femur fractures, the screws should not be either placed within the cement mantle or make direct contact with the stem.

Publisher

SAGE Publications

Subject

Mechanical Engineering,General Medicine

Cited by 6 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3