Affiliation:
1. Unit of Radiotherapy, Istituto Nazionale Tumori, Milan, Italy
2. Unit of Medical Physics, Istituto Nazionale Tumori, Milan, Italy
Abstract
Aims and background We designed a comparative planning study aimed at quantifying the advantages of intensity-modu-lated radiotherapy (IMRT) over the conventional 3-field technique (3FT) and a 5-field conformal technique (5FCT) for head and neck (HN) cancer. Methods We selected 9 patients treated at our institution with curative radiotherapy for a HN cancer. For all cases 4 plans were generated: 2 plans using the “standard” techniques (3FT and 5FCT), a third plan using IMRT, and a fourth “mixed” plan using IMRT followed by a conventional boost. Results Our study confirmed literature data on the ability of IMRT to significantly decrease the dose received by organs at risk, compared with previous techniques. Target coverage was systematically better with 5FCT and IMRT than with 3FT. However, the increase in coverage of both PTV2 and PTV1 was only about 3-5% and this was achieved at the price of a similar increase in maximum dose (D1%). Volumetric parameters (V100%, V95%) were much more sensitive in detecting the improvement with IMRT. Conclusions The improvement of target coverage attained by IMRT, as compared with conventional and conformal techniques, might be overestimated by data currently available in the medical literature. If treatment with conventional techniques is planned using all tools provided by currently available fully 3-D planning systems, excellent target coverage can be obtained.
Subject
Cancer Research,Oncology,General Medicine
Cited by
10 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献