3D-Conformal Radiation Therapy in Prostate Cancer. Technical Considerations after 5 Years of Experience and 334 Patients Treated at the Istituto Europeo Di Oncologia of Milan, Italy

Author:

Ghilezan Michel1,Ivaldi Giovanni1,Cattani Federica2,Greco Carlo1,Castiglioni Simona1,Leonardi Maria Cristina1,Tosi Giampiero2,Marsiglia Hugo1,Orecchia Roberto13

Affiliation:

1. Department of Radiation Oncology, Italy

2. Medical Physics Unit, European Institute of Oncology, Milan, Italy

3. University of Milan, Italy

Abstract

Aims and Background To report the technique of 3D-conformal radiation therapy (3D-CRT) currently used at our Institute for the treatment of prostate cancer with a curative intent. A critical review of the technical aspects of the technique is provided. Methods and Study Design Between December 1995 and October 2000, 334 patients with biopsy-proven adenocarcinoma of the prostate were treated with 3D-CRT. All patients were treated in a prone position with 15 MV X-ray beams and a 6-field technique for all but 20 patients, who were treated with a 3-field technique. Patients were simulated with the rectum and bladder empty. To ensure reproducible positioning, custom-made polyurethane foam or thermoplastic casts were produced for each patient. Subsequently, consecutive CT scan slices were obtained. The clinical target volume and critical organs (rectum and bladder) were identified on each CT slice. The beam's eye view technique was used to spatially display these structures, and the treatment portals were manually shaped based on the images obtained. The beam apertures were initially realized by conventional Cerrobend blocks (48 patients), which were replaced in October 1997 by a computer-driven multi-leaf collimator. The total target dose prescribed at the ICRU point is 76 Gy, delivered in 38 fractions and 54 days. The seminal vesicles are excluded at 70 Gy. Dose-volume histograms were obtained for all patients. If more than 30% of the bladder and/or more than 20% of the rectum receive >95% of the prescribed total dose, the treatment plan is judged as unsatisfactory and is adjusted. The dose-volume histogram can be improved by changing the beam's arrangement and/or weights or by introducing or modifying the wedge filters. Conclusions 3D-CRT in prostate cancer patients is a highly sophisticated and time-consuming method of dose delivery. Important technical issues remain to be clarified.

Publisher

SAGE Publications

Subject

Cancer Research,Oncology,General Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3