Combining Independent Studies of Diagnostic Fluorodeoxyglucose Positron-Emission Tomography and Computed Tomography in Mediastinal Lymph Node Staging for Non-Small Cell Lung Cancer

Author:

Alongi Filippo1,Ragusa Pietro2,Montemaggi Paolo3,Bona Cristina Maria4

Affiliation:

1. Radiotherapy, Istituto Scientifico San Raffaele, Milan;

2. Dipartimento di Scienze Statistiche e Matematiche, Università degli Studi “Silvio Vinelli”, Palermo;

3. Radiotherapy Unit, Regional Cancer Center M. Ascoli, Palermo;

4. Radiotherapy Unit, Istituto per la Ricerca e la Cura del Cancro, Candiolo (TO), Italy

Abstract

Aims and background A meta-analysis of diagnostic test performance was conducted to compare the results of relevant studies reporting diagnostic accuracy values for mediastinal staging in patients with non-small cell lung cancer (NSCLC). This paper deals with the two most accurate imaging techniques currently in use: positron emission tomography (PET) with FDG and computed tomography (CT). A statistical pooling method was used to perform a quantitative meta-analysis aimed at demonstrating the potential advantage of one of these two methods. Methods Studies in all languages published between 1998 and 2005 that examined the use of FDG-PET and CT for mediastinal staging in NSCLC patients, enrolled at least 18 participants, and provided enough data to allow calculation of sensitivity and specificity rates were considered eligible for the quantitative meta-analysis. Statistical methods to pool the overall estimates of sensitivity and specificity and to compare the discriminant power of PET and CT were discussed and used. Results Of the 13 studies included in the analysis, 12 reported greater accuracy of FDG-PET than CT in detecting mediastinal lymph node metastases. The sensitivity of FDG-PET ranged from 50% to 100%. The estimate of the overall sensitivity was 0.83% with 95% CI (0.749–0.913). Specificity ranged from 79% to 100%, with an overall estimated specificity of 0.87% with 95% CI (0.80–0.95). For CT, the sensitivity and specificity ranged from 50% to 97% and 58% to 94%, respectively; the overall estimate was 0.68% with 95% CI (0.582–0.788) and 0.76% with 95% CI (0.668–0.859). The summary receiver operating characteristic (SROC) approach was used to assess the superior diagnostic accuracy of one of the two methods. The areas under the two SROC curves were AUCPET = 0.909 vs AUCCT = 0.794. Conclusions Numerical and visual results of the meta-analysis of recent relevant reports agreed that FDG-PET is more accurate than CT in identifying mediastinal lymph node metastases in non-small cell lung cancer.

Publisher

SAGE Publications

Subject

Cancer Research,Oncology,General Medicine

Cited by 25 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3