Daily On-Line Set-Up Correction in 3D-Conformal Radiotherapy: Is It Feasible?

Author:

Deodato Francesco1,Cilla Savino2,Gabriella Macchia1,Massaccesi Mariangela1,Ippolito Edy13,Caravatta Luciana1,Picardi Vincenzo1,Romanella Michele1,Di Falco Carlo4,Bartollino Alessandra5,Valentini Vincenzo6,Cellini Numa6,De Spirito Marco2,Piermattei Angelo2,Morganti Alessio G16

Affiliation:

1. Radiotherapy Unit, Department of Oncology

2. Medical Physics Unit, Università Cattolica, Campobasso

3. Radiotherapy Department, Campus Biomedico, Rome, Italy

4. Fondazione di Ricerca e Cura “Giovanni Paolo II”, Università Cattolica, Campobasso

5. Service of Clinical Engineering, Fondazione di Ricerca e Cura “Giovanni Paolo II”, Università Cattolica, Campobasso

6. Radiation Oncology Department, Policlinico A Gemelli, Università Cattolica, Rome.

Abstract

Aims and background The aim of this report was to investigate the feasibility in terms of treatment time prolongation of an on-line no-action level correction protocol, based on daily electronic portal image verification. Methods and study design The occupation of a linear accelerator (LINAC) delivering 3-D conformal treatments was monitored for two weeks (from Monday to Friday, 10 working days). An electronic portal image device I-View (Elekta, UK) was used for setup verification. Single-exposure portal images were acquired daily using the initial 8 monitor units delivered for each treatment field. Translational deviations of isocenter position larger than 5 mm or 7 mm, for radical or palliative treatments, respectively, were immediately corrected. In order to estimate the extra workload involved with the on-line protocol, the time required for isocenter check and table correction was specifically monitored. Results Forty-eight patients were treated. In all, 482 fractions had electronic portal images taken. Two hundred and forty-five setup corrections were made (50.8% of all fractions). The occupation of the LINAC lasted 106 h on the whole. Twelve h and 25 min (11.7% of LINAC occupation time) were spent for portal image verification and setup correction. On the average, 4.3 fractions per hour were carried out. Conclusions When used by trained therapists, ideally, portal imaging may be carried out before each fraction, requiring approximately 10% of LINAC occupation time.

Publisher

SAGE Publications

Subject

Cancer Research,Oncology,General Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3