The Variability of Applicator Position among High Dose Rate Intracavitary Brachytherapy Applications in Cervical Cancer Patients Treated with Ring & Tandem Applicators

Author:

Ebruli Cuneyt1,Demiral Ayşe Nur2,Çetingöz Riza2,Eyiler Ferhat3,Kinay Münir2

Affiliation:

1. Kocaeli State Hospital Radiation Oncology Clinic, Kocaeli

2. Dokuz Eylul University Medical School Department of Radiation Oncology, Ízmir

3. Adana State Hospital Radiation Oncology Clinic, Adana, Turkey

Abstract

Objective To evaluate the interindividual and intraindividual applicator position variability in high dose rate ring and tandem intracavitary brachytherapy applications in locally advanced cervical cancer. Patients and Methods Eight patients with locally advanced cervical cancer formed the study population. They had been treated in Dokuz Eylül University Department of Radiation Oncology between the years 2000 and 2005 with high dose rate intracavitary brachytherapy using ring and tandem applicators. The 3-dimensional geometric variation of the applicator center in craniocaudal, mediolateral and anteroposterior directions was determined on the basis of bony reference points in 24 pairs of orthogonal films obtained in the conventional simulator. Then the following evaluations were performed: 1) the applicator position variability in all applications (interindividual variability), 2) the intraindividual applicator position variability relative to the first application, 3) the intraindividual applicator position variability relative to the average of three applications. Among the potential factors that might influence the reproducibility of ring and tandem applications, age, stage, the period between external radiotherapy and brachytherapy were evaluated by univariate analysis. Results Standard deviation of interindividual applicator variability was 3.83 mm in craniocaudal, 0.39 mm in mediolateral and 2.86 mm in anteroposterior directions. The standard deviation of intraindividual variability relative to the first application was 1.91 mm in craniocaudal, 0.4 mm in mediolateral, and 4.26 mm in anteroposterior directions. The standard deviation of intraindividual variability relative to the average of three applications was 0.95 mm in craniocaudal, 1.86 mm in mediolateral, and 1.24 mm in anteroposterior directions. According to univariate analysis, no factor influenced applicator position variability. Conclusions In order to extract definitive conclusions about factors that affect positional reproducibility of ring and tandem applicators, studies are needed that include larger numbers of patients.

Publisher

SAGE Publications

Subject

Cancer Research,Oncology,General Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3