Long-Term Stability of the Electronic Sensor Component of a Digital Pill System in Real-World Storage Settings

Author:

Chai Peter R.1234ORCID,Goodman Georgia25,Bustamante Majo J.2,Mohamed Yassir2,Castillo-Mancilla Jose6,Boyer Edward W.12,Mayer Kenneth H.27,Rosen Rochelle K.8,Baumgartner Susan L.9,Buffkin Eric9,O’Cleirigh Conall25

Affiliation:

1. Brigham and Women’s Hospital, Boston, MA, USA

2. The Fenway Institute, Boston, MA, USA

3. Dana Farber Cancer Institute, Boston, MA, USA

4. Massachusetts Institute of Technology, Cambridge, MA, USA

5. Massachusetts General Hospital, Boston, MA, USA

6. University of Colorado–Anschutz Medical Campus, Aurora, CO, USA

7. Beth Israel Deaconess Medical Center, Boston, MA, USA

8. The Miriam Hospital, Providence, RI, USA

9. etectRx Inc, Gainesville, FL, USA

Abstract

Background: Digital pill systems comprise an ingestible sensor integrated into a gelatin capsule that overencapsulates medication allowing real-time measures of medication ingestion. These systems may improve the manner in which medication adherence can be assessed and supported. Objective: In this investigation, we tested the durability of the ingestible sensor as part of a clinical trial to measure the feasibility and acceptability of the system to measure adherence to once daily tenofovir disoproxil fumarate/emtricitabine (NCT03842436). Methods: Digital pills not dispensed during the study were stored in a pharmacy. Seventeen sensors were selected from digital pills stored for at least 12 months and activated in a simulated gastric environment. A radiofrequency spectrum analyzer and the reader device used in the clinical trial to capture ingestion events were used to measure activation of emitters. A passing evaluation was defined as an energized emitter within 30 minutes of immersion, ability to broadcast a signal for 10 minutes, and successful acquisition by the reader. Results: All ingestible sensors passed the stability test. Mean activation time in simulated gastric fluid was 3.33 minutes (SD = 1.47); emitters remained active for a mean of 47.72 minutes (SD = 1.78). These parameters matched guidelines defined in the ID-Cap system requirements for use in patients. Conclusions: Ingestible sensor components of the ID-Cap system were therefore stable after long-term storage.

Publisher

SAGE Publications

Subject

Pharmaceutical Science