Background: The use of smart pump technology has shown to be profitable in the intensive care unit (ICU) because it avoids costs from prevented medication errors and allows for savings on disposables and medications by establishing standardized concentrations and dosing units. Objective: The objective of the study is to evaluate the economic impact of the implementation of smart infusion pumps in the consumption of intravenous (IV) solutions in an ICU. Methods: A retrospective observational study was conducted with a pre-post design. The study occurred in the adult ICU of the Hospital Juárez de México. The pattern of consumption of IV solutions (sodium chloride 9%, Hartmann’s solution, dextrose 5% and 10%, sodium chloride 0.9% with dextrose 5%) was analyzed preimplementation and postimplementation of 50 Plum A+™ pumps with Hospira MedNet™ security software. Using the TreeAge Pro 2016 software, deterministic and probabilistic analyses were carried out (10 000 Monte Carlo simulations) to confirm the robustness of the annual consumption comparison and the associated expenses before and after implementing smart technology. Results: The implementation of the smart pumps reduced the annual consumption of IV solutions to 8994 units (18%) and 3649 liters (22.3%). In the first year, MXN$55 850.97 were saved. From an institutional perspective and with a probability of 0.63, the use of MedNet™ technology proved to be a lower cost alternative (17.1% saved) with respect to the conventional infusion systems. Conclusion: The implementation of smart infusion pumps allows savings, specifically for the IV solutions used in ICU.

Publisher

SAGE Publications

Subject

Pharmacology (medical),Pharmacology,Pharmacy

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3