Effects of sedation with dexmedetomidine and buprenorphine on echocardiographic variables, blood pressure and heart rate in healthy cats

Author:

Johard Einar1,Tidholm Anna12,Ljungvall Ingrid2,Häggström Jens2,Höglund Katja3

Affiliation:

1. Anicura Albano Animal Hospital, Danderyd, Sweden

2. Department of Clinical Sciences, Faculty of Veterinary Medicine, Swedish University of Agricultural Sciences, Uppsala, Sweden

3. Department of Anatomy, Physiology and Biochemistry, Faculty of Veterinary Medicine, Swedish University of Agricultural Sciences, Uppsala, Sweden

Abstract

Objectives Sedative agents are occasionally used to enable echocardiographic examination when screening cats for heart disease, such as hypertrophic cardiomyopathy (HCM). Owing to their haemodynamic effects, sedative agents may alter echocardiographic measurements. The aim of the study was to evaluate the effects of the sedative combination dexmedetomidine and buprenorphine on echocardiographic variables, blood pressure (BP) and heart rate (HR) in healthy cats. Methods Fifty healthy, client-owned cats were prospectively recruited and included after physical examination. Cats were sedated intramuscularly with dexmedetomidine and buprenorphine, according to body weight. Blood pressure and HR measurements, echocardiographic and Doppler examinations were performed prior to sedation and repeated once cats had achieved acceptable sedation. Results Left ventricular internal diameter at end-diastole and systole, right ventricular internal diameter at end-diastole, left atrium (LA), pulmonary artery (PA) deceleration time, and systolic, diastolic and mean arterial blood pressure increased after sedation ( P ⩽0.022). Aortic and PA maximum velocity, fractional shortening, PA acceleration/deceleration time and HR decreased after sedation ( P <0.0001). Interventricular septum at end-diastole and systole, left ventricular posterior wall at end-diastole and systole, aortic diameter (Ao), left atrial/aortic diameter (LA/Ao) and pulmonic acceleration time did not change. Conclusions and relevance Blood pressure increased and HR decreased post-sedation. While wall thickness and LA/Ao were not affected by sedation, indices of LA and left ventricular size increased. Further studies are needed using cats with HCM to assess the effect of this sedative combination on HCM screening results.

Publisher

SAGE Publications

Subject

Small Animals

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3