Effects of positive end-expiratory pressure and 30% inspired oxygen on pulmonary mechanics and atelectasis in cats undergoing non-bronchoscopic bronchoalveolar lavage

Author:

Bernhard Christa,Masseau Isabelle1,Dodam John,Outi Hilton,Krumme Stacy,Bishop Kaitlin,Graham Amber,Reinero Carol

Affiliation:

1. Current address: Department of Clinical Sciences, Faculty of Veterinary Medicine, University of Montréal, Québec, Canada

Abstract

Objectives The objective of this study was to determine if modification of inspired oxygen concentration or positive end-expiratory pressure (PEEP) would alter bronchoalveolar lavage (BAL)-induced changes in pulmonary mechanics or atelectasis, as measured using ventilator-acquired pulmonary mechanics and thoracic CT. Methods Six experimentally asthmatic cats underwent anesthesia and non-bronchoscopic BAL, each under four randomized treatment conditions: 100% oxygen, zero PEEP; 30% oxygen, zero PEEP; 100% oxygen, PEEP 2 cmH2O; and 30% oxygen, PEEP 2 cmH2O. Pulse oximetry was used to estimate oxygen saturation (SpO2). Ventilator-acquired pulmonary mechanics and thoracic CT scans were collected prior to BAL and at 1, 5 and 15 mins post-BAL. Results While receiving 100% oxygen, no cat had SpO2 <91%. Some cats receiving 30% oxygen had decreased saturation immediately post-BAL (mean ± SD 70.8 ± 31%), but 6/8 of these had SpO2 >90% by 1 min later. There was a significant increase in airway resistance and a decrease in lung compliance following BAL, but there was no significant difference between treatment groups. Cats receiving no PEEP and 30% oxygen conserved better aeration of the lung parenchyma in BAL-sampled areas than those receiving no PEEP and 100% oxygen. Conclusions and relevance Alterations in pulmonary mechanics or atelectasis may not be reflected by SpO2 following BAL. The use of 30% inspired oxygen concentration failed to show any significant improvement in pulmonary mechanics but did diminish atelectasis. In some cats, it was also associated with desaturation of hemoglobin. The use of PEEP in this study did not show any effect on our outcome parameters. Further studies using higher PEEP (5–10 cmH2O) and intermediate inspired oxygen concentration (40–60%) are warranted to determine if they would confer clinical benefit in cats undergoing diagnostic BAL.

Publisher

SAGE Publications

Subject

Small Animals

Cited by 3 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3