Automated Volume Measurement of the Syndesmosis Using 3D Weightbearing CT

Author:

Guss Daniel,Lucchese Olivia,Ashkani-Esfahani Soheil,Bhimani Rohan,Waryasz Gregory R.,Kerkhoffs Gino,Lubberts Bart,DiGiovanni Christopher W.

Abstract

Category: Ankle; Trauma; Other Introduction/Purpose: Recent studies have shown that weight-bearing computed tomography (WBCT) that allows 3D volume measurement of the distal syndesmosis while under physiologic load brings about a higher accuracy in detection of syndesmotic instability, especially if subtle. Since the volume measurement method is complex, time-consuming, and has a noticeable interobserver bias, most clinicians might not still be interested in utilizing it in practice. Automatization of this measurement using computer-assisted methods will not only reduce the interobserver bias but also will be faster and more applicable in practice. This study aimed to develop an automated 3D syndesmosis volume measurement tool using image processing methods and compare the speed and the interobserver bias with human interpreters. Methods: We included 30 patients with subtle syndesmotic instability who had undergone WBCT and were diagnosed intraoperatively. Thirty individuals with otherwise healthy ankles who had WBCT images were allocated to the control group. The volume measurement up to 5cm proximal to the tibial plafond was considered as the most sensitive and specific method to assess syndesmotic stability based on the literature. An algorithm was developed using MATLAB software that could recognize and calculate the syndesmotic volume using WBCT images. The volume measurement method was used by two orthopaedic surgeons for the same population. The time spent by each surgeon and the algorithm was measured. Finally, the values were compared using the t-test; the interobserver correlation coefficient (ICC) was also calculated. P<0.05 was considered statistically significant. Results: The percentage of changes in 3D volume showed a significant difference at 5cm (25.4%; p<0.001), proximal to the tibial plafond. Based on our clinical study, the volume measurement up to 5cm showed a sensitivity of 95.8%, 95%CI:87.8-100, and specificity of 83.3%, 95% CI:68.4-98.2 for detection of syndesmotic instability. The ICC between the clinicians was 75% while using the automated measurement algorithm showed an ICC of 97%. The mean time spent by the clinicians was 268.4+-56.4 and by the algorithm was 2.9+-0.3 seconds (p<0.001, Figure 1). Conclusion: Given the fact that 3D volume measurement of the syndesmosis using WBCT is still a complex technique for most clinicians while it is one of the most accurate diagnostic methods based on recent literature, developing a faster and more accurate method for 3D volume measurement of the syndesmosis leads to a more reliable and easier to use the technique to be used in practice.

Publisher

SAGE Publications

Subject

General Medicine

Cited by 3 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3