Functional, Spiroergometric, and Subjective Comparisons Between Forearm Crutches and Hands-Free Single Crutches in a Crossover Study

Author:

Yao Daiwei12ORCID,Meyer-Kobbe Louisa3,Ettinger Sarah24ORCID,Claassen Leif25,Altemeier-Sasse Anna24,Sturm Christian6,Kerling Arno6,Stukenborg-Colsman Christina2,Plaass Christian2

Affiliation:

1. ATOS Orthopedic Clinic Braunfels, Braunfels, Germany

2. Department for Foot and Ankle Surgery, DIAKOVERE Annastift, Orthopedic clinic of the Hannover Medical School, Hannover, Germany

3. Hannover Medical School, Hannover, Germany

4. University Hospital for Orthopedics Pius Hospital Oldenburg, Oldenburg, Germany

5. Orthoprofis Hannover, Hannover, Germany

6. Department for Rehabilitation- and Sports Medicine, Hannover Medical School, Hannover, Germany

Abstract

Background: Following below-knee surgery, the optimal medical mobility device remains controversial as adequate nonweightbearing of the operated extremity is critical to ensure successful healing. The use of forearm crutches (FACs) is well established but requires using both upper extremities. The hands-free single orthosis (HFSO) is an alternative that spares the upper extremities. This pilot study compared functional, spiroergometric, and subjective parameters between HFSO and FAC. Methods: Ten healthy (5 females, 5 males) participants were asked to use HFSOs and FACs in a randomized order. Five functional tests were performed: climbing stairs (CS), an L-shaped indoor course (IC), an outdoor course (OC), a 10-meter walk test (10MWT), and a 6-minute walk test (6MWT). Tripping events were counted while performing IC, OC, and 6MWT. Spiroergometric measurements consisted of a 2-step treadmill test with speeds of 1.5 and 2 km/h, each for 3 minutes. Lastly, a VAS questionnaire was completed to collect data regarding comfort, safety, pain, and recommendations. Results: Significant differences between both aids were observed in CS and IC (HFSO: 29.3 seconds; FAC: 26.1 seconds, P < .03; and HFSO: 33.2 seconds, FAC: 18 seconds, P < .001, respectively). The other functional tests showed no significant differences. The trip events were not significantly different between the use of the 2 aids. Spiroergometric tests showed significant differences regarding heart rate (HFSO: 131.1 bpm at 1.5 km/h and 131 bpm at 2 km/h; FAC: 148.1 bpm at 1.5 km/h and 161.8 bpm at 2 km/h) and oxygen consumption (HFSO: 15.4 mL/min/kg at 1.5 km/h and 16 mL/min/kg at 2 km/h; FAC: 18.3 mL/min/kg at 1.5 km/h and 21.9 mL/min/kg at 2 km/h) at both speeds (all P < .01). In addition, significantly different ratings regarding the items comfort, pain, and recommendation were recorded. Both aids were equally rated for safety. Conclusion: HFSOs may be an alternative to FACs, especially in activities that require physical stamina. Further prospective studies in patients with below-knee surgical intervention concerning everyday clinical use would be interesting. Level of Evidence: Level IV pilot-study.

Publisher

SAGE Publications

Subject

Orthopedics and Sports Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3