Clinical Outcomes and Cadaveric Biomechanical Analysis of Endoscopic Percutaneous Achilles Tendon Rupture Repair With Absorbable Suture

Author:

Carpenter Daniel1,Dederer Katherine2,Weinhold Paul3,Tennant Joshua N.3ORCID

Affiliation:

1. EmergeOrtho, Raleigh, NC, USA

2. Panorama Orthopedics and Spine Center, Golden, CO, USA

3. University of North Carolina at Chapel Hill School of Medicine, Chapel Hill, NC, USA

Abstract

Background: Percutaneous repair of acute Achilles tendon rupture (ATR) continues to gain in popularity. The primary aim of the study was to review the outcomes of a patient cohort undergoing a novel technique of endoscopic percutaneous Achilles tendon repair with absorbable suture. A secondary purpose of this study was to evaluate the basic biomechanical properties of the technique. Methods: A cohort of 30 patients who underwent percutaneous ATR repair was retrospectively analyzed with Achilles Tendon Rupture Scores (ATRS), complications, and additional outcome measures. For a biomechanical analysis portion of the study, 12 cadaveric specimens were paired and randomized to either novel percutaneous repair or open Kessler repair with absorbable suture. These specimens were subjected to 2 phases of cyclical testing (100 cycles 10-43 N followed by 200 cycles 10-86 N) and ultimate strength testing. Results: In the clinical portion of the study we report excellent patient reported outcomes (mean ATRS 94.1), high level of return to sport, and high patient satisfaction. One partial re-rupture was reported but with no major wound or neurologic complications. In the biomechanical portion of the study we found no significant difference in tendon gapping between percutaneous and open repairs in phase 1 of testing. In phase 2, increased gapping occurred between percutaneous (17.8 mm [range 10.7-24.1, SD 6.4]) and open repairs (10.8 mm [range 7.6-14.9, SD 2.7, P = .037]). The ultimate load at failure was not statistically different between the 2 repairs. Conclusions: A percutaneous ATR repair technique using endoscopic assistance and absorbable suture demonstrated low complications and good outcomes in a cohort of patients, with high satisfaction, and excellent functional outcomes including high rates of return to sport. Cadaveric biomechanical testing demonstrated excellent survival during testing and minimal increase in gapping compared with open repair technique, representing sufficient strength to withstand forces seen in early rehabilitation. A percutaneous Achilles tendon repair technique with absorbable suture may minimize risks associated with operative repair while still maintaining the benefit of operative repair. Level of Evidence: Level IV, retrospective case series.

Publisher

SAGE Publications

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3